DS7200V2-EXP | Installation Guide | 4. Reference Materials
EN | 121
Programming Issues
Problem
Cause
Solution
I cannot enter into
Programming Mode.
One or more Areas are armed.
Programming may be disabled.
If one or more Areas are armed,
disarm all armed Areas.
Programming mode cannot be
entered if an Area is armed (unless
you are using an Installer’s
Keypad).
Programming may be disabled. See
“Local Programming Options” in
the DS7240 Expert Programming
Guide (Address 0257). Enable
Keypad Programming and PK32
(Program Key) through RPS or by
using an Installer’s Keypad.
I have enabled Open/Close
reports, but when I arm the
panel Perimeter Only, these
reports are still not sent.
“Open/Close Reports for Perimeter
Only” is not programmed correctly.
See Area # Opening {89-96}/Closing {42-
67} Reporting Options on page 66.
Enable the “Open/Close Reports for
Perimeter Only Mode” option by
entering a 4, 5, 6, 7, 12, 13, 14 or 15 in
the appropriate address (0296, 0318,
0340 or 0362).
The PK32 (Program Key) does
not work (upload, download,
erase, etc.).
The PK32 has not been enabled in the
control panel firmware.
See “Local Programming Options” in
the DS7240 Expert Programming Guide
(Address 0257) to enable the PK32.
The off-board zones I added to
the system display as missing.
The Device Location parameter is
not correctly programmed.
If the off-board zones are RF
(wireless) zones, enable the RF
Receiver at Address 1249.
See Location ##, Zone Function on page
83. Verify which device type has been
added (for example, RF zone, off-board
zone, etc.). In the Device Location
parameter, enter the correct value
based on the Device Parameter
Selections:
1 = On-board
2 = DX2010
3 = DX2010, Doubled
4 = RF Receiver 1
5 = RF Receiver 2
Zone configuration is locked into only
those configuration types in the Device
Parameter Selections.
The system is not following
report routing as
programmed.
The Lock Area Reporting parameter is
enabled.
Disable Lock Area Reporting. See the
DS7200V2 Expert Programming Guide
(P/N: 4998153891) for instructions.
Keypad Issues
Problem
Cause
Solution
I entered the Move to Area
function ([#][5][0]) at my
keypad, but it does not let me
move to another area.
The Move to Area function is disabled
if there are no zones assigned to a
particular Area.
Program at least one zone and assign it
to an Area. The Move to Area function
should work as defined.