DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 96
3.7 Sked Parameters
Skeds are programmable events that occur at a specified time of day and day of the week.
Users can extend Auto On, Auto Perimeter Only On and Auto Partial On time by one hour using the
Extend Auto On Time function ([#][5][1]). When [#][5][1] is entered, the control panel sends an Auto
On Extended {21} report.
Users can also change Skeds using the Change Skeds function ([#][5][2]). A Sked must first be
entered before the Change Skeds function is used.
The following sections and parameters detail the programming of each of the eight Skeds. The
parameters in Output Parameters on page 86 determine the characteristics of the output activation
that occurs at the Sked time.
See Table 38 for Sked configuration parameter addresses.
The default setting for all Sked parameters is 0 (zero).
Table 38: Sked Configuration Parameters
Sked
Type
Assign
(Area or
Output)
Time
Days 1
Option
Days 2
Option
(H _ _ _)
(_H _ _)
(_ _ M _)
(_ _ _ M)
1 Addr
1184
Addr
1185
Addr
1186
Addr
1187
Addr
1188
Addr
1189
Addr
1190
Addr
1191
2 Addr
1192
Addr
1193
Addr
1194
Addr
1195
Addr
1196
Addr
1197
Addr
1198
Addr
1199
3 Addr
1200
Addr
1201
Addr
1202
Addr
1203
Addr
1204
Addr
1205
Addr
1206
Addr
1207
4 Addr
1208
Addr
1209
Addr
1210
Addr
1211
Addr
1212
Addr
1213
Addr
1214
Addr
1215
5 Addr
1216
Addr
1217
Addr
1218
Addr
1219
Addr
1220
Addr
1221
Addr
1222
Addr
1223
6 Addr
1224
Addr
1225
Addr
1226
Addr
1227
Addr
1228
Addr
1229
Addr
1230
Addr
1231
7 Addr
1232
Addr
1233
Addr
1234
Addr
1235
Addr
1236
Addr
1237
Addr
1238
Addr
1239
8 Addr
1240
Addr
1241
Addr
1242
Addr
1243
Addr
1244
Addr
1245
Addr
1246
Addr
1247
Type, Sked #
Address: See Table 38
Default: 0 (No type assigned)
Selections:
- 0 = No Type Assigned (Sked disabled)
- 1 = Auto All On
- 2 = Auto Perimeter Only On
- 3 = Auto Partial On
- 4 = Auto Off
- 5 = Output On (DS7240V2: Outputs 1 to 15; DS7220V2: Outputs 1 to 12)
- 6 = Output Off (DS7240V2: Outputs 1 to 15; DS7220V2: Outputs 1 to 12)
The Sked Types "Output Function On" and "Output Function Off" override any output function at Sked
time (except for Alarm Output Functions 1|8 to 1|12). For example, an output function that turns a
light on is overridden by a Sked that turns the same light on.