DS7200V2-EXP | Installation Guide | 2. System Installation
and Setup
EN | 22
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Figure 23: PO 1 Positive Alarm Trigger
Wiring
1- Audible notification appliance
2.4.3 Programmable Outputs 2 to 4 (PO 2 to
PO 4)
PO 2 can be used with ALRM+ as a supervised
siren driver. Connect an approved 4 or 8
speaker. Alternatively, PO 2 can sink up to 500
mA 12 VDC. See Figure 24.
Figure 24: PO 2 to PO 4 Wiring
1- Audible notification appliance
If PO 2 is configured as a supervised
siren driver (in combination with the
ALRM + terminal), you must connect a
4 or 8 speaker to PO 2 to clear the
speaker supervision trouble.
PO 3 and PO 4 can be configured for Alarm
Output. These outputs can sink up to 500 mA
12 VDC each.
Defaults for PO 2 to PO 4 are as follows:
PO 2: 1|6 (Strobe)
PO 3: 0|1 (Armed: All, Perimeter Only, Partial On)
PO 4: 2|13 (Ready to Arm)
See Output Parameters on page 86 for
programming instructions.
If PO 1 to PO 4 do not provide the alarm output
you expect, do the following:
Check the programming for Programmable
Outputs in Output Parameters on page 86.
Check “Zone Function Configuration” in the
DS7200V2 Expert Programming Guide
(P/N: 4998153891) to verify the zones you are
activating are programmed for alarm output.
2.5 RF3227E RF Receiver Setup
For complete installation instructions regarding
the RF3227E Premises RF Receiver, see the
RF3227E Installation Guide (P/N: 4998122415).
2.5.1 RF Receiver Addressing
Set the RF3227E’s address by placing the
address jumper pin as shown in Figure 25.
Remove power from the system and
RF receiver so that RF receiver
address changes can take effect.
Figure 25: RF3227E Address Jumper
Settings
1- RF receiver address jumper pins
2- RF Receiver #1 (Address 50) jumper plug OFF
(default position)
3-
RF Receiver #2 (Address 51) jumper plug ON
1
BATT+
BATT-
PO1
L-1
SMK
+
PO1 SELECT
COM
(+)
(-)
A B
ALRM
+