DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 81
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Table 30: Location Configuration Parameters (continued)
These columns show the addresses and
defaults for each of the four location
parameters. These parameters configure
each location. Shaded cells only apply
to the DS7240V2.
Device Parameter Selections
These columns show the selections for the “Device” parameter. The Device parameter
tells the control panel where to find the sensor loop (or transmitter) status for each
location.
DX2010
1
Doubled
Device = 3
DACM
3
Device = 6
(optional)
DBus Adr 106
Loop 5; 2.2 k
DBus Adr 106
Loop 6; 2.2 k
DBus Adr 106
Loop 7; 2.2 k
DBus Adr 106
Loop 8; 2.2 k
DBus Adr 107
Loop 1; 3.65 k
DBus Adr 107
Loop 2; 3.65 k
DBus Adr 107
Loop 3; 3.65 k
DBus Adr 107
Loop 4; 3.65 k
DBus Adr 107
Loop 5; 3.65 k
Loop 6
Loop 6; 3.65 k
Xmitter 30
Xmitter 30
DBus Adr 107
Loop 7; 3.65 k
DBus Adr 107
Loop 8; 3.65 k
DBus Adr 107
Loop 1; 2.2 k
DBus Adr 107
Loop 2; 2.2 k
DBus Adr 107
Loop 3; 2.2 k
DBus Adr 107
Loop 4; 2.2 k
DBus Adr 107
Loop 5; 2.2 k
DBus Adr 107
Loop 6; 2.2 k
Loop 7
Loop 7; 2.2 k
Xmitter 39
51Xmitter 39
DBus Adr 107
Loop 8; 2.2 k
1
DBus = Data Bus
2
Xmitter = Transmitter
3
DACM = DACM door contact. Integrating the DACM door contact into the security system is optional.
See
DACM Configuration
on page 105 for instructions on integrating the DACM door contact into the
security system.