DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 54
The End Page Field follows the Format Field. The digits you enter in this field are sent after the
paging message. For many paging services, a ‘#’ indicates the end of the paging message. The
End
Page Field ends with a Field Terminator (0).
You must enter the pauses required for the paging service in the Digits to Dial Field before
the Digits to Dial field terminator.
The number of pauses required varies based on the paging service.
Test the pager to determine that you entered enough pauses to establish communications
to the paging service.
Table 25: Format Field Options
Format Field
Resulting Pager Display
Empty Account, Event, Area, and Zone
Numbers with separator characters.
1234-008-03-21
# Account, Event, Area, and Zone
Numbers without separator characters.
12340080321
*** Account, Event, and Area Numbers with
separator characters.
1234-008-03
#*** Account, Event, and Area Numbers
without separator characters.
123400803
** Account and Event Numbers with
separator characters.
1234-008
#** Account and Event Numbers without
separator characters.
1234008
* Account Number only. 1234
If the zone/user number is three digits, the leading digit is omitted. For example, “252”
displays as “52.”
Do not use alpha characters for the account number in basic pager format.