Mode (Steady, Pulse, One Shot), Output ##
Address: See Table 33 on page 86
Default: See Table 33 on page 86
Selections: 1 to 13 (see Table 35)
There are two types of outputs: state-driven outputs and event-driven outputs. State-driven outputs
follow the state of a condition, either on or off. For example, a state-driven output is Type 0|1 Armed.
The output is active when the control panel is armed and inactive when the control panel is disarmed.
Event-driven outputs follow events when they occur. These events have no On or Off state. For
example, an event-driven output is Type 0|13 Ack Received. When the key is pressed, the output is
activated.
Table 35 describes the mode operation for both on-board and off-board outputs.
Table 35: Output Mode Options
Mode
Mode Type
Output
Type
Description
1 Steady State Output turns on when the condition is active and turns off when the condition is
inactive.
Event Output turns on when the event occurs. [System Reset] turns the output off.
2 Latch State Output turns on when the condition is active and remains on until [System Reset] is
pressed.
Event Output turns on when the event occurs and remains on until [System Reset] is
pressed.
3 Toggle State When the condition goes from inactive to active, the output changes state. The
condition going from active to inactive has no effect.
Event Whenever the event occurs, the output changes state.
4 Pulse State When the condition is active, the output pulses. When the condition is inactive, the
output is off.
Event When the event occurs, the output pulses. The output remains pulsing until [System
Reset] is pressed.
5 One-Shot State When the condition changes from inactive to active, the output turns on. The output
turns off at the end of the One-Shot time. While the output is on, any changes in the
condition are ignored.
Event When the event occurs, the output turns on and remains on for the One-Shot time.
When the output is on, a second event does not affect the output.
6 One-Shot
with Re-
Trigger
State When the condition changes from inactive to active, the output turns on and remains
on for the One-Shot time. If the condition goes inactive and active again, the One-
Shot time is restarted and the output remains on.
Event When the event occurs, the output turns on and remains on for the One-Shot time. If
a new event occurs when the output is on, the One-Shot time is restarted and the
output remains on.
7 One-Shot
with Reset
State When the condition changes from inactive to active, the output turns on and remains
on for the One-Shot time. If the condition goes inactive, the output is turned off early.
Event When the event occurs, the output turns on and remains on for the One-Shot time.
[System Reset] turns the output off early.
8 Steady,
Reversed
Logic Normal
State Output turns on when the condition is inactive and turns off when the condition is
active.
Event
Output turns off when the event occurs. [System Reset] turns the output on.