2.2 Arming Device Installation
The Door Access Control Module (DACM) is also
an arming device. See Door Access Control Module
(DACM) on page 38 for more information.
2.2.1 Keypad Addressing
Keypads 1 to 8 are assigned to Data Bus
Addresses 1 to 8.
Table 3 shows the correct address setting for
each keypad address.
Table 3: Keypad Address Pin Settings
0* OFF OFF OFF OFF OFF OFF
1
OFF OFF OFF OFF
2 OFF
OFF OFF OFF
3
OFF OFF OFF
4 OFF OFF
OFF OFF
5
OFF
OFF OFF
6 OFF
OFF OFF
7
OFF OFF
8 OFF OFF OFF
OFF
* Address 0 is reserved for the Installer Keypad.
This keypad is not intended for permanent
installation and should remain with the
installer/service technician.
Some keypads use jumper plugs to set the
address. See Figure 7 for correct jumper plug
orientation.
Figure 7: Keypad Jumper Plug
Configuration
1- Jumper plug ON position
2-
Jumper plug OFF positions
2.2.2 Keypad Installation
Keypads contain static-sensitive
components. Follow anti-static
procedures when handling the
keypads.
Consult your keypad’s installation manual for
complete installation instructions. Keypads
connect to the control panel in parallel as shown
in Figure 8.
Figure 8: Keypad to Control Panel Wiring
1- DS7447E/DS7445i Keypads, or
DS7447V2/DS7445V2 Keypads
2- Keypad terminal block
3- Green data wire
4- Yellow data wire
5- Red (+12 VDC) wire
6- Black (-12 VDC) wire
You can use either one of the Aux Power (-)
terminals and either one of the 12 VDC (+)
terminals when connecting devices to the control
panel.
See Table 4 for control panel data bus-to-keypad
wire length requirements.
Table 4: Keypad to Control Panel Wire Length
Control Panel to Keypad 305 m
(1000 ft)
610 m
(2000 ft)
Control Panel to Keypad
using an External Power
Supply
305 m
(1000 ft)
610 m
(2000 ft)
BATT+
BATT-
7
Data In
Data Out
+12 VDC
Com
1
2 3 4
6
5
(+)
(-)