DS7200V2-EXP | Installation Guide | 4. Reference Materials
EN | 109
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Table 40: Control Panel Events and Reporting Formats
Event as shown
in Control Panel
Log
Zone Types
Linked to
Event
01 AC Fail
AT AC Trouble
301 AC Loss AC Power to panel interrupted. 12 R S
02 AC Restore
AR AC Restoral
301 AC Loss AC Power to panel restored. 12 R S
03 Alarm,Tamper
TA Tamper
Alarm
137 Tamper Alarm, Tamper Zone Type. 4-Tamper 3
04* Alarm,Emergenc
y
QA Emergency
Alarm
101 Personal
Emergency
Alarm, Emergency Zone Type
or ABC key programmed for
emergency response. [Q]
button.
5- Emergency 3
05* Alarm,Panic PA Panic Alarm 120 Panic Alarm, Panic-Visible Zone Type.
[Q] button.
6- Visible
Panic
3
06* Alarm,Invisible HA Holdup
Alarm
120 Panic Alarm, Panic- Invisible Zone
Type or ABC key programmed
for panic response. [Q] button.
7-Invisible
Panic
3
07 Alarm,24-hr Burg BA Burglary
Alarm
133 24 Hr
Safe
Alarm, Burglary Zone Type. 8- Burglary
15 - Door
3
08 Alarm,Cntrl,Dly BA Burglary
Alarm
134
Entry/Exit
Alarm, Delay 1 or Delay 2 Zone
Type.
11- E/E Delay
1
12- E/E Delay
2
3
09 Alarm,Cntrl BA Burglary
Alarm
130 Burglary Alarm, Keyswitch or Follower
or Instant Zone Types.
10- Keyswitch
13- Follower
14- Instant
3
10 Cross,Tamper BM Burglary
Alarm Cross
Zone
137 Tamper Alarm, Tamper Zone Type with
Cross Zone Option selected.
4-Tamper 3
11 Cross,Emergenc
y
BM Burglary
Alarm Cross
Zone
101 Personal
Emergency
Alarm, Emergency Zone Type
with Cross Zone Option
selected.
5- Emergency 3
12 Cross,Panic BM Burglary
Alarm Cross
Zone
120 Panic Alarm, Panic-Visible Zone Type
with Cross Zone Option
selected.
6- Visible
Panic
3
13 Cross,Invisible BM Burglary
Alarm Cross
Zone
120 Panic Alarm, Panic- Invisible Zone
Type with Cross Zone Option
selected.
7-Invisible
Panic
3
* Keypad [A], [B], or [C] keys report as Zones 100, 101, and 102. The [Q] button on a keyfob reports
as User Number +200. See the DS7200V2 Expert Programming Guide (P/N: 4998153891) for
information on [Q] button programming.