DS7200V2-EXP | Installation Guide | 4. Reference Materials
EN | 110
Table 40: Control Panel Events and Reporting Formats (continued)
Event
Event as shown
in Control Panel
Log
SIA Report
Contact ID
Report
Event Description
Zone Types
Linked to
Event
RPS
Event
Group
Status
Report
14 Cross,24hr Burg
BM Burglary
Alarm Cross Zone
133 24 Hr Safe
Alarm, Burglary Zone Type with
Cross Zone Option selected
8- Burglary 3
15 Cross,Cntrl,Dly
BM Burglary
Alarm Cross Zone
134 Entry/Exit
Alarm, Delay 1 or Delay 2 Zone
Type with Cross Zone Option
selected.
11- E/E Delay 1
12- E/E Delay 2
3
16 Cross,Cntrl
BM Burglary
Alarm Cross Zone
130 Burglary
Alarm, Follower or Instant Zone
Types with Cross Zone Option
selected.
13- Follower
14- Instant
3
17 Cross,Unverified
BG Unverified
Event Burglary
378 Cross-zone
Trouble
A fault on one non-fire zone type
with the Cross Zone Option
selected. This is not an alarm
event.
any with Cross
Zone Option
3
18 Alarm Exit Error EA Exit Alarm
374 Exit Error
(zone)
Zone faulted at the end of Exit
Delay.
11- E/E Delay 1
12- E/E Delay 2
3
19 Alrm Recent Clse
CR Recent
Closing
134 Entry/Exit
Alarm event within 2 min. of
closing.
11- E/E Delay 1
12- E/E Delay 2
3
20 Alrm Recent Clse
CR Recent
Closing
130 Burglary
Alarm event within 2 min. of
closing.
10- Keyswitch
13- Follower
14- Instant
3
21 Auto On Extended
CE Closing
Extend
464 Auto-arm
Time Extended
Auto On Sked delayed one hour by
user. Report follows Open/Close
routing.
10
22 Battery Low
YT System Battery
Trouble
302 Low
System Battery
Panel battery is low. 12 R S
23 Battery Missing
YM System
Battery Missing
311 Battery
Missing/Dead
Panel battery is missing. Very low,
shorted, or open batteries are
reported as missing.
12 R S
24 Rstrl Batt Low
YR System
Battery Restoral
302 Low
System Battery
Battery restoral from low battery. 12 R S
25 Rstrl Bat Missng
YR System
Battery Restoral
311 Battery
Missing/Dead
Battery Restoral from missing
battery.
12 R S
26 Bypass,Fire,User FB Fire Bypass
571 Fire
bypass
Selective bypass by user, fire zone
types.
1- Fire
2- Fire with
Alarm
Verification
15
27 Bypass,Fire,
RPS
FB Fire Bypass
571 Fire
bypass
Selective bypass by RPS, fire zone
types.
1- Fire
2- Fire with
Alarm
Verification
28 Bypass,Ctrl,User
BB Burglary
Bypass
570
Zone/Sensor
bypass
Selective bypass by user,
controlled zone types.
10 to 15- Zone
Types
15
29 Bypass,Ctrl, RPS
BB Burglary
Bypass
570
Zone/Sensor
bypass
Selective bypass by RPS, zone
types.
10 to 15- Zone
Types
30 Bypass,24hr,User
BB Burglary
Bypass
572 24-Hr Zone
Bypass
Selective bypass by user, 24-hour
non-fire zone types.
3 to 9- 24-hour,
Non-Fire Zone
Types
15