DS7200V2-EXP | Installation Guide | 4. Reference Materials
EN | 111
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Table 40: Control Panel Events and Reporting Formats (continued)
Event as shown
in Control Panel
Log
Zone Types
Linked to
Event
31 Bypass,24hr,
RPS
BB Burglary
Bypass
572 24-Hr
Zone Bypass
Selective bypass by RPS, 24-hour
non-fire zone types.
3 to 9- 24-hour,
Non-Fire Zone
Types
32 Bypass,Forced Zn BB Burglary
Bypass
570
Zone/Sensor
Zone force armed at force
arming.
10 to 15- Zone
Types
15
33 Bypass,Swinger BB Burglary
Bypass
575 Swinger
Shunt
Zone Swinger Shunted. All zone types 15
34 UnBypss,Fire, Usr FU Fire
UnBypass
571 Fire
bypass
User cleared bypass (unbypass),
Fire zone types.
1- Fire
2- Fire with
Alarm
Verification
15
35 UnBypss,Ctrl,Usr BU Burglary
Unbypass
570
Zone/Sensor
bypass
User cleared bypass (unbypass),
controlled zone types.
10 to 15- Zone
Types
15
36 UnBypss,24hr,Usr BU Burglary
Unbypass
572 24-Hr
Zone Bypass
User cleared bypass (unbypass),
24-hour zone types.
3 to 9- 24-hour,
Non-Fire Zone
Types
15
37 Call for Service YX Service
Required
616 Service
Request
This report sent automatically at
Call for Service Interval. It does
not indicate a trouble condition.
12 R
38 Cancel Alarm BC Burglary
Cancel
406 Cancel User acknowledged active alarm
before Bell Time expired, non-fire
zone types.
8
39 Cancel Fire FC Fire Cancel 406 Cancel User acknowledged active alarm
before Bell Time expired, fire
zone types.
7
40 CheckSum Fail YF Parameter
Checksum Fail
303 RAM
Checksum
Bad
Checksum on panel’s parameters
failed. Panel program should be
verified.
12 R S
41 ChkSum Fail,DBus YF Parameter
Checksum Fail
330 System
Peripheral
trouble
Checksum on Option Bus device
parameters failed. Device should
be checked.
12 R S
42 Cls,All,+Dly,Skd CA Automatic
Closing
403 Automatic
O/C
System turned All On with
Entry/Exit Delay by Sked.
10
43 Cls,All,+Dly,KS CS Closing
409 Keyswitch
System turned All On with
Entry/Exit Delay by Keyswitch.
10
44 Cls,All,+Dly, RPS CQ Remote
Closing
400
Open/Close
System turned All On with
Entry/Exit Delay by RPS.
45 Cls,All,+Dly,Tel CQ Remote
Closing
407 Remote
Arm/Disarm
System turned All On with
Entry/Exit Delay by Telephone.
10
46 Cls,All,+Dly,Usr CL Closing
Report
401 O/C by
User
System turned All On with
Entry/Exit Delay by User.
10
47 Cls,All,-Dly,RPS CQ Remote
Closing
400
Open/Close
System turned All On with no
delay (instant) by RPS.
48 Cls,All,-Dly,Usr CL Closing
Report
401 O/C by
User
System turned All On with no
delay (instant) by User.
10
49 Cls,Prt,+Dly,Skd CA Automatic
Closing
456 Partial
Arm
System armed Perimeter Only
with Entry/Exit delay by Sked.
10
50 Cls,Prt,+Dly,KS CS Closing
Keyswitch
442 Keyswitch
Armed Stay
System armed Perimeter Only
with Entry/Exit Delay by
Keyswitch.
10