DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 80
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
3.5 Zone Parameters
The DS7240V2 supports Locations 1 to 40. The DS7220V2 supports Locations 1 to 24. Locations
become zones by configuring the following parameters: Device, Zone Function, Area, and Zone
Number. All four of these parameters must be configured for each location being used in the system.
See Table 30 for location parameter addresses and defaults (defaults are shown in bold).
Table 30: Location Configuration Parameters
These columns show the addresses and
defaults for each of the four location
parameters. These parameters configure each
location.
Device Parameter Selections
These columns show the selections for the “Device” parameter. The Device parameter tells the control
panel where to find the sensor loop (or transmitter) status for each location.
DX2010
1
Doubled
Device = 3
DACM
3
Device = 6
(optional)
DBus Adr 106
Loop 1; 3.65 k
DBus Adr 106
Loop 2; 3.65 k
DBus Adr 106
Loop 3; 3.65 k
DBus Adr 106
Loop 4; 3.65 k
DBus Adr 106
Loop 5; 3.65 k
DBus Adr 106
Loop 6; 3.65 k
DBus Adr 106
Loop 7; 3.65 k
DBus Adr 106
Loop 8; 3.65 k
DBus Adr 106
Loop 1; 2.2 k
DBus Adr 106
Loop 2; 2.2 k
DBus Adr 106
Loop 3; 2.2 k
DBus Adr 106
Loop 4; 2.2 k
1
DBus = Data Bus
2
Xmitter = Transmitter
3
DACM = DACM door contact. Integrating the DACM door contact into the security system is optional.
See
DACM Configuration
on page 105 for instructions on integrating the DACM door contact into the
security system.