DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 80
3.5 Zone Parameters
The DS7240V2 supports Locations 1 to 40. The DS7220V2 supports Locations 1 to 24. Locations
become zones by configuring the following parameters: Device, Zone Function, Area, and Zone
Number. All four of these parameters must be configured for each location being used in the system.
See Table 30 for location parameter addresses and defaults (defaults are shown in bold).
Table 30: Location Configuration Parameters
Location Parameters
These columns show the addresses and
defaults for each of the four location
parameters. These parameters configure each
location.
Device Parameter Selections
These columns show the selections for the “Device” parameter. The Device parameter tells the control
panel where to find the sensor loop (or transmitter) status for each location.
Location
Device
Zone
Function
Area
Zone #
On-board
Device = 1
DX2010
1
Device = 2
DX2010
1
Doubled
Device = 3
RF Rcvr 1
1,2
Device = 4
RF Rcvr 2
1,2
Device = 5
DACM
3
Device = 6
(optional)
1
0706
(1)
0707 (11)
0708
(1)
0709, 0710
(0,1)
3.65 k
when
doubled w/9
DBus Adr 101
Loop 1
DBus Adr 50
Xmitter 1
DBus Adr 51
Xmitter 1
DACM
2
0711
(1)
0712 (11)
0713
(1)
0714, 0715
(0,2)
3.65 k
when
doubled w/10
DBus Adr 101
Loop 2
DBus Adr 50
Xmitter 2
DBus Adr 51
Xmitter 2
DACM
3
0716
(1)
0717 (12)
0718
(1)
0719, 0720
(0,3)
3.65 k
when
doubled w/ 11
DBus Adr 101
Loop 3
DBus Adr 50
Xmitter 3
DBus Adr 51
Xmitter 3
DACM
4
0721
(1)
0722 (13)
0723
(1)
0724, 0725
(0,4)
3.65 k

when
doubled w/ 12
DBus Adr 101
Loop 4
DBus Adr 50
Xmitter 4
DBus Adr 51
Xmitter 4
DACM
5
0726
(1)
0727 (13)
0728
(1)
0729, 0730
(0,5)
3.65 k

when
doubled w/ 13
DBus Adr 101
Loop 5
DBus Adr 50
Xmitter 5
DBus Adr 51
Xmitter 5
DACM
6
0731
(1)
0732 (14)
0733
(1)
0734, 0735
(0,6)
3.65 k

when
doubled w/ 14
DBus Adr 101
Loop 6
DBus Adr 50
Xmitter 6
DBus Adr 51
Xmitter 6
DACM
7
0736
(1)
0737 (14)
0738
(1)
0739, 0740
(0,7)
3.65 k

when
doubled w/ 15
DBus Adr 101
Loop 7
DBus Adr 50
Xmitter 7
DBus Adr 51
Xmitter 7
DACM
8
0741
(1)
0742
(4)
0743
(1)
0744, 0745
(0,8)
3.65 k

when
doubled w/ 16
DBus Adr 101
Loop 8
DBus Adr 50
Xmitter 8
DBus Adr 51
Xmitter 8
DACM
9
0746
(0)
0747
(0)
0748
(1)
0749, 0750
(0,9)
Doubled w/ 1
2.2 k
DBus Adr 102
Loop 1
DBus Adr 106
Loop 1; 3.65 k
DBus Adr 50
Xmitter 9
DBus Adr 51
Xmitter 9
DACM
10
0751
(0)
0752
(0)
0753
(1)
0754, 0755
(1,0)
Doubled w/ 2
2.2 k
DBus Adr 102
Loop 2
DBus Adr 106
Loop 2; 3.65 k
DBus Adr 50
Xmitter 10
DBus Adr 51
Xmitter 10
DACM
11
0756
(0)
0757
(0)
0758
(1)
0759, 0760
(1,1)
Doubled w/ 3
2.2 k
DBus Adr 102
Loop 3
DBus Adr 106
Loop 3; 3.65 k
DBus Adr 50
Xmitter 11
DBus Adr 51
Xmitter 11
DACM
12
0761
(0)
0762
(0)
0763
(1)
0764, 0765
(1,2)
Doubled w/ 4
2.2 k
DBus Adr 102
Loop 4
DBus Adr 106
Loop 4; 3.65 k
DBus Adr 50
Xmitter 12
DBus Adr 51
Xmitter 12
DACM
13
0766
(0)
0767
(0)
0768
(1)
0769, 0770
(1,3)
Doubled w/ 5
2.2 k
DBus Adr 102
Loop 5
DBus Adr 106
Loop 5; 3.65 k
DBus Adr 50
Xmitter 13
DBus Adr 51
Xmitter 13
DACM
14
0771
(0)
0772
(0)
0773
(1)
0774, 0775
(1,4)
Doubled w/ 6
2.2 k
DBus Adr 102
Loop 6
DBus Adr 106
Loop 6; 3.65 k
DBus Adr 50
Xmitter 14
DBus Adr 51
Xmitter 14
DACM
15
0776
(0)
0777
(0)
0778
(1)
0779, 0780
(1,5)
Doubled w/ 7
2.2 k
DBus Adr 102
Loop 7
DBus Adr 106
Loop 7; 3.65 k
DBus Adr 50
Xmitter 15
DBus Adr 51
Xmitter 15
DACM
16
0781
(0)
0782
(0)
0783
(1)
0784, 0785
(1,6)
Doubled w/ 8
2.2 k
DBus Adr 102
Loop 8
DBus Adr 106
Loop 8; 3.65 k
DBus Adr 50
Xmitter 16
DBus Adr 51
Xmitter 16
DACM
17
0786
(0)
0787
(0)
0788
(1)
0789, 0790
(1,7)
DBus Adr 103
Loop 1
DBus Adr 106
Loop 1; 2.2 k
DBus Adr 50
Xmitter 17
DBus Adr 51
Xmitter 17
DACM
18
0791
(0)
0792
(0)
0793
(1)
0794, 0795
(1,8)
DBus Adr 103
Loop 2
DBus Adr 106
Loop 2; 2.2 k
DBus Adr 50
Xmitter 18
DBus Adr 51
Xmitter 18
DACM
19
0796
(0)
0797
(0)
0798
(1)
0799, 0800
(1,9)
DBus Adr 103
Loop 3
DBus Adr 106
Loop 3; 2.2 k
DBus Adr 50
Xmitter 19
DBus Adr 51
Xmitter 19
DACM
20
0801
(0)
0802
(0)
0803
(1)
0804, 0805
(2,0)
DBus Adr 103
Loop 4
DBus Adr 106
Loop 4; 2.2 k
DBus Adr 50
Xmitter 20
DBus Adr 51
Xmitter 20
DACM
1
DBus = Data Bus
2
Xmitter = Transmitter
3
DACM = DACM door contact. Integrating the DACM door contact into the security system is optional.
See
DACM Configuration
on page 105 for instructions on integrating the DACM door contact into the
security system.