2.1.7 RAM Backup Battery Installation
The control panel uses a 3 V coin-type lithium
battery to save system settings, including
date/time and programming settings.
Remove the insulator tab from between the
battery and battery clip before completing
system installation.
Figure 4: RAM Backup Battery
1- RAM Backup Battery
2- Battery Clip
3- Insulator -
2.1.8 Telephone Connections
See System Status LED on page 40 for a complete
function description.
1. To prevent jamming of signals, wire the
RJ31X jack or RJ38X jack to support line
seizure as shown in Figure 5.
2. Install the jack on the street side of the
phone switch, wired ahead of any PBX
equipment. Line seizure temporarily
interrupts normal phone usage while the
communicator transmits data.
3. Confirm that the panel seizes the line,
acquires dial tone, reports correctly to the
receiver, and releases the phone line to the
in-house phone system.
Figure 5: RJ31X/RJ38X Wiring
1- Outside Telco (PSTN)
2- Premises telephone
3- RJ31X or RJ38X jack
4- Telco connector block
5- Phone line connections to control panel
6- Bar short removed on Telco connector
block insertion – positions 1 & 4 and 5 & 8
4. Connect the telephone cord’s flying leads to
the telephone terminals (Red to R; Gray to
R1; Brown to T1; Green to T). The terminals
are located on the right side of the control
panel board.
5. Plug the other end of the cord to the RJ31X
jack or RJ38X jack.