Table 34: Output Function Types (continued)
Digit
1
Digit
2
Function Type
Description
5 1 Trouble Zone Function 1 These 15 output functions activate for troubles on any zone assigned to
the specified Zone Function. They reset when none of the zones
assigned to the specified Zone Function are in trouble.
to
5 15 Trouble Zone Function 15
6 0 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).
6 1 Follow PIN 1 These output functions activate when the specified PIN is entered.
Output Function Type 7, 12 follows User 28, which can be programmed
as the Guard Code User (see page 78).
These output types are event-driven. See Mode (Steady, Pulse, One Shot),
Output ## on page 93 for more information.
PIN area assignments are ignored when these output functions are
selected.
to
6 15 Follow PIN 15
7 0 Follow PIN 16
to
7 15 Follow PIN 31
8 0 Follow PIN 32
8 1 Sked Only This output type is only available for Outputs 1 to 15. Activated by
Skeds. See Assign (Area or Output), Sked # on page 97 for more
information.
8 2 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).
8 3 Always On Output is always activated.
8 4 Verified Alarm Activates when the requirements for a verified alarm are met. Resets
when a PIN is entered.
8 5 Unverified Alarm Activates on any non-24-hr alarm, 24-hr tamper or 24-hr burglary alarm.
Resets when the verified alarm timer resets or when a PIN is entered.
8 6 Tamper Activates on any tamper condition. Resets when the tamper condition
restores.
8 7 Bypass Activates when any input is bypassed. Resets when all input bypasses
are cleared.
8 8 Enhanced Siren Activates on Exit Delay, Entry Delay, Chime, Alarm, Tamper, Trouble, or
Bad Set. Resets at the end of bell time or when a PIN is entered.
8 9 Alarm Cancel Activates on a cancelled alarm. Resets when alarm is cleared.
8 10 RF Transmitter Missing Activates when any RF transmitter is missing. Restores by pressing
[System Reset].
8 11 RF Transmitter Low Battery Activates when any RF transmitter is reporting a low battery. Resets by
pressing [System Reset].
8 12 RF Receiver Jamming Activates when RF Jamming is present. Resets by pressing [System
Reset].
8 13 Fire Alarm Only Activates on Fire Alarm only. PIN resets. Does not pulse in Temporal
Code 3 format.
8 14 Personal Alarm Activates when one of its assigned areas is set to Personal Alarm. Resets
by entering a valid user PIN, pressing the [System Reset] key, or by RPS
(System Reset command). Activates on any of the following conditions:
(1) If a Duress User PIN is entered (2) If an Emergency key is active in an
area and “Activate Panic Alarm Response” and “Alarm Output” are
enabled for the key (3) If a RF keyfob reports a Panic alarm (4) If a zone
configured for 24-hr Visible Panic (Zone Function Type 6) goes into
alarm, or (5) Certain [Q] button configurations. See the DS7200V2
Expert Programming Guide (P/N: 4998153891) for [Q] button
information.
8 15 [Q] Button Output activates when the [Q] button is pressed on a RF keyfob. For
Steady or Pulse modes, [System Reset] resets. This output function type
is event-driven. See Mode (Steady, Pulse, One Shot), Output ## on page
93 for more information.