DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 91
Table 34: Output Function Types (continued)
Digit
1
Digit
2
Function Type
Description
2 0 [P] Key (Rising Sun Key on RF
Fob)
Activates when Rising Sun Key on RF Keyfob is pressed. [System Reset]
resets. Pressing P (sun) key again also resets output when Output Mode
is set to Toggle. This output type is event-driven. See Mode (Steady,
Pulse, One Shot), Output ## on page 93 for more information.
2 1 ‘Panic’ on RF Fob Activates when Arm Key (locked icon) and Disarm Key (unlocked icon)
on RF Keyfob are pressed at the same time, or when the [Q] button is
pressed and it is set to Duress. See the DS7200V2 Expert Programming
Guide (P/N: 4998153891) for [Q] button information. [#][4][7] resets.
2 2 ‘Panic’ on RF Fob, Bell Time,
PIN resets
Activates when Arm Key (locked icon) and Disarm Key (unlocked icon)
on RF Keyfob are pressed at the same time, or when the [Q] button is
pressed and it is set to Duress. Steady and Pulse modes follow bell time.
PIN resets.
2 3 [A] Key Activates when appropriate keys are pressed. [System Reset] resets if no
alarm response is assigned. These output types are event-driven. See
Mode (Steady, Pulse, One Shot), Output ## on page 93 for more
information.
2 4 [B] Key
2 5 [C] Key
2 6 3 Unsuccessful Dialing
Attempts
Activates after 3 unsuccessful dialing attempts. Resets with first
successful call or [System Reset].
2 7 Communication Fail Event Activates after Communication Fail Event. Resets with any successful
communication or [System Reset].
2 8 Panel Off Hook Activates when the control panel takes the phone line off hook for a
dialing attempt. Resets when the control panel finishes with the phone
line and goes on hook.
2 9 Ring Detect Activates when the control panel detects a ring on the phone line. Resets
when ringing stops.
2 10 Voice Request For use with an optional Voice Verification Module. The output activates
for 2 sec when the control panel receives an acknowledgement of an
alarm report from a zone with the Voice Verification option enabled.
Mode and Time parameters do not apply.
2 11 Follow Keypad Sounder Available for on-board outputs only. Output follows keypad sounder
Mode and Time parameters do not apply.
2 12 Chime Activates per Chime configuration. Follows keypad sounder per Chime
Tone configuration.
2 13 Ready to Arm (No zones
faulted)
Output is activated (on) when: (1) control panel is disarmed & no zones
are faulted (2) control panel is armed & no zones are faulted (3) control
panel is armed and any zone is faulted. Output is deactivated (off) when
control panel is disarmed & any zone is faulted. Output is deactivated
even if the zone became faulted when control panel was armed.
2 14 Exit Error/Bad Set Activates if zone is faulted at the end of Exit Delay or if a Bad Set
condition occurs. Resets when the system is disarmed.
2 15 AC 60 Hz Activates on 60 Hz. Deactivates on 50 Hz.
3 0 Ground Start Activates for approximately 0.5 sec at the start of any dialing attempt.
Use to bring up dial tone in ground start phone systems.
3 1 Follow Zone Function 1 These 15 output functions activate for any fault on any zone assigned to
the specified Zone Function.
to
3 15 Follow Zone Function 15
4 0 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).
4 1 Alarm Zone Function 1 These 15 output functions activate for alarms on any zone assigned to
the specified Zone Function and the area(s) the output is assigned to.
They reset when none of the zones assigned to the specified Zone
Function are in alarm.
to
4 15 Alarm Zone Function 15
5 0 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).