DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 56
RPS Answer Ring Count, Answering Machine Bypass
Address: 0213
Default: 7 (rings)
Selections:
- 0 = Control panel does not answer phone
- 1-13 = Ring Count
- 14 = Answering Machine Bypass 1
- 15 = Answering Machine Bypass 2
The ring count sets the number of rings the control panel waits before picking up and seizing the
phone line for a remote programming session, or for remote arming with a telephone (see Arming
Options 1 on page 62).
The control panel does not answer the phone for remote programming or remote arming with
telephone when this parameter is set to zero (0).
This ring count is used for any control panel arming state, armed or disarmed.
The Answering Machine Bypass function can be restricted to only operate when the system is armed
All On or Perimeter Only (see Arming Options 1 on page 62). When the Answering Machine Bypass
function is restricted to only operate when the system is armed All On or Perimeter Only, the control
panel does not answer the phone for a remote arming session when it is disarmed (Off). However,
[#][4][3] still initiates a remote programming session.
Answering Machine Bypass 1
1. Call the premises; let the phone ring no more than two (2) times. Then hang up/disconnect the
remote programmer.
2. Wait at least eight (8) sec to call back, but call back within 45 sec.
3. The control panel then picks up after the first ring.
Answering Machine Bypass 2
1. Call the premises; let the phone ring no more than four (4) times. Then hang up/disconnect the
remote programmer.
2. Wait at least eight (8) sec to call back, but call back within 45 sec.
3. The control panel then picks up after the first ring.