DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 69
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
User Tamper Retry Count
• Address: 0381
• Default: 4 (4 attempts)
• Selections:
- 0 = User Retry Count Disabled
- 1 to 15 = Number of attempts allowed before a User Tamper event occurs
Enter zero (0) to disable this parameter. The control panel creates a User Tamper event when a user
enters an invalid PIN the number of times programmed in this parameter.
For example, “5” is entered in this parameter. When an invalid PIN is entered five times, a User
Tamper event occurs.
User Tamper Lockout Time
• Address: 0382
• Default: 1 (1 minute)
• Selections: 0 to 15 (min.)
This parameter determines how long a keypad is locked out when a User Tamper event occurs
(selections are in min).
Installer PIN
• Address: 0383 to 0389
• Default: 9876543
• Selections: 0 to 9
Do not use digits 10-15 when creating the Installer PIN or User PIN. Entering these digits
makes the PIN unusable and locks the installer out of the control panel.
The Installer PIN length is the same as all other system PINs (see PIN Length on page 68).
The default PIN length is 4 digits, which makes the Installer PIN 4 digits in length. For example, if the
Installer PIN is 7654321 and the PIN length is set to 4 digits, the Installer PIN changes to 7654.
The Installer PIN cannot disarm the system, but it can access all other functions.
The Installer PIN reports as User 0.
If the Installer PIN is left at its factory default, the control panel generates a System
Trouble event if enabled in the Date Format and Enable PIN Trouble parameter (see the
DS7200V2 Expert Programming Guide (P/N: 4998153891). Make sure to change the default
value. This event is Local Only and is stored in the history buffer.
The Enable PIN Trouble option is disabled by default.