DS7200V2-EXP | Installation Guide | 3. Control Panel
Programming
EN | 72
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Area Option, User #
• Address: See Table 10
• Default:
- User 1:
- DS7240V2: 15 (Areas 1 to 4)
- DS7220V2: 3 (Areas 1 and 2)
- Users 2 to 32: 0 (Not assigned to an area)
• Selections: 0 to 15
Enter This Data Digit to Select Options
Assigning PINs to multiple areas allows users to view and operate multiple areas from a single keypad.
RF ID for Keyfob
You must exit control panel programming in order to enter the RF ID code. Add RF ID codes after you
complete your programming session. See Adding RF ID Codes on page 42 for complete instructions.
3.4.3 Keypads
Wired Keypads 1 to 8 are fixed at Data Bus Addresses 1 to 8. See Keypad Addressing on page 15 for
more information. All keypads (and other Data Bus devices) are fully supervised. Supervision reports,
such as missing and tamper reports, follow the System Status Report routing.
Keypad # Options
• Address:
- Keypad 1: 0678
- Keypad 2: 0680
- Keypad 3: 0682
- Keypad 4: 0684
- Keypad 5: 0686
- Keypad 6: 0688
- Keypad 7: 0690
- Keypad 8: 0692
• Default: 7
• Selections: 0 to 15
Enter This Data Digit to Select Options
Beep Keypad on System Trouble
Enable Area Display (DS7446KP Keypad)
Don’t Show Zone Status on Keypads
• Beep Keypad on System Trouble: If enabled, this option sounds a tone at the keypad when a
System Trouble occurs.
• Enable Exit Tone: If enabled, this option sounds the Exit Delay tone at this keypad when Exit
Delay is active.