PD6662 and DD243 Requirements
To comply with PD6662 and DD243, you must meet all of the EN50131-3 requirements and the
following requirements:
Maintenance: A qualified technician must check the system at least twice a year.
AC Power Supply:
Type: A
Rated Voltage: 230 V
Rated Input Frequency: 50 Hz
Rated Input Current: 250 mA maximum
Fuse Rating: 0.25 A, 250 V Slow Blow
Construction Materials: Enclosures and housings for the control panel, control center,
DX2010, wireless receiver, and wireless devices are made from materials that are
durable, secure, and resistant to attack by hand-held tools.
Confirmed Alarms: Set Expert Programming Item Number 124 to either Option 3 or 4.
Refer to System Programming Items, page 48 for more information.
The Easy Series control panel is designed to comply with PD6662:2004 as a Grade 2 system
that supports Notification Options A, B, C, or X with the appropriate notification devices
installed (devices not included with system).
EN50131 Requirements
The Easy Series control panel is designed to comply with EN50131-1 Security Grade 2,
Environmental Class II.
Installation, Programming, and Maintenance
Installation: Refer to Install System Components, page 25.
Programming: Refer to Programming, page 43.
Testing: Refer to System Test and Maintenance, page 66.
Maintenance: Refer to System Test and Maintenance, page 66.
Automatic Inhibit
Intruder Alarm and Fault Signal or Message: Set Expert Programming Item Number 131 to a value between 1 and
3.
Refer to System Programming Items, page 48 for more information.
Authorization Code: Set Expert Programming Item Number 892 to a value between 3 and 8.
Refer to Control Center Programming Items, page 60 for more information.
Logical and Physical Keys
Minimum Number of Combinations per User:
Passcodes: 15,625 (passcode length must be six digits)
Tokens: 42,000,000,000
Key Fobs: 2,800,000,000,000,000
Method Used to Determine Number of Combinations:
Passcodes: Digits 1 to 5 are allowed. For a six-digit passcode, all combinations are allowed.
Tokens: 32 bits. All combinations are allowed.
Key Fobs: 56 bits (48 serialized during manufacturing, 8 remain static)
1.6
1.7
Easy Series Control Panel Agency Approvals and Requirements | en 11
Bosch Security Systems, Inc. System Reference Guide 2014.09 | 01 | F.01U.306.221