Control Center Programming Items
Speech Configuration Items
Programming Item Item
Number
Selections Manuf.
Defaul
t
Alarm Message Minimum Repeat Time 880 (1 to 255 hrs). 12
"No Alarm Report Sent" Announcement 883 0 = Announcement disabled.
1 = Announcement enabled.
1
"Cancel Report Sent" Announcement 884 1
Time Format 887 0 = Determined by voice module
1 = Always use 12-hr mode
2 = Always use 24-hr mode
0
Global Control Center Items
These programming items affect all control centers connected to the control panel.
To send a user fire, emergency (medical) or panic report, the appropriate control center
button and report must be enabled. Refer to Route Reporting Options, page 54 to enable
reports.
Check the appropriate box in the Easy Series User Guide (P/N: F01U025111B) to identify
which buttons are enabled.
Programming Item Item
Number
Selections Manuf.
Defaul
t
Fire Button Alarm 888 0 = Disabled.
1 = Enabled.
0
Medical Button Alarm 889 0 = Disabled.
1 = Enabled
0
Panic Button Alarm 890 0 = Disabled.
1 = Enabled (audible).
2 = Enabled (silent).
0
One Button Arming
[i]
891 0 = Disabled (token or passcode required).
1 = Enabled (token or passcode is not required).
0
Invalid Passcode Attempt Limit 892 3 to 8. 3
Control Center Lockout Time 893 1 to 30 min. 3
Individual Control Center Items
Programming Item Item Number Selections Manuf. Default
Control Center
Brightness
Control Center 1: 811 1 (dim) to 5 (bright). Control Center 1: 5
Control Center 2: 821 Control Center 2: 5
Control Center 3: 831 Control Center 3: 5
Control Center 4: 841 Control Center 4: 5
5.2.8
60 en | Programming Easy Series Control Panel
2014.09 | 01 | F.01U.306.221 System Reference Guide Bosch Security Systems, Inc.