To comply with EN50131-1, set these programming items as follows:
Programming Item Item Number Setting Section Starting
Page
Programming Key Auto Transfer 123 Select Option 0 System
Programming
Items, page 48
Entry Delay 127 Set to 45 sec or less
Swinger Bypass Count 131 Select Option 3
Restrict Installer Passcode 142 Select Option 1
RPS Automatic Call In Frequency 224 Select Option 0 RPS
Configuration
Items, page 54
Passcode Length 861 Set passcode length to six digits User
Programming
Items, page 61
INCERT
To comply with INCERT, set these programming items as follows:
Programming Item Item Number Default Section Starting Page
Restrict Installer Passcode 142 1 System Programming
Items, page 48
Passcode Length 861 6 digits
Invalid Passcode Attempt 892 3*
Control Center Lockout Time 893 3* User Programming Items,
page 61
* To comply with INCERT, set these programming items to 3 or higher.
cUL
For Canadian installations, install systems according to ULC-S302. Systems that use the
C900V2 Conettix IP Dialer Capture Module meet Level 3 Line Security when communicating
over a packet-switched data network (PSDN).
NF A2P
If you modify system parameters you are responsible for maintaining the system within the
scope of the standard and regulations that apply to the hardware and/or the system in which
it is used. In a NF A2P compliant installation, use only NF A2P listed components, and check
that each parameter is in the authorized range.
Note: RADION devices have not been evaluated by Afnor for NF A2P compliance.
Accessories Authorized in a Certified Installation
Part Description
IUI-EZ1-NEW Control center
NP17-12IFR 17AH Yuasa battery
ICP-EZPK Flash memory