When installing the magnet, verify that the notches in the magnet base, line up with the
notches in the transmitter base, otherwise the magnet and transmitter do not function
effectively.
When installing the magnet base, install the face of the magnet base flush to the surface
edge of the installation location. This prevents damage to the magnet plastic base
whenever a window or door is opened.
Adhere to the distances prescribed in the graphical table found in the graphical
Installation and Operation Guide when installing the magnet adjacent to the transmitter.
How to read the Graphical Magnet Distances table
Contained in the RADION contact SM Installation Guide is a graphical table along with the X
Y
Z coordinates graphic. Use the table in conjunction with the graphic to determine desired
distances between the magnet and the transmitter based on the type of installation (wood or
metal).
Notice!
The content in the Installation Guide table applies to EN installations.
RADION contact RM
The RFDW-RM is a recessed-mounted wireless transmitter device used for monitoring doors
and windows. Features include:
Self-contained transmitter with magnetic reed switch
Tamper protection
Recessed mounting on doors or windows
Power/voltage One AAA Lithium battery, 1.5 VDC ( )
Power source type: C
Low battery level: 0.9V
Battery replacement Energizer L92. Check your battery yearly to ensure proper
functionality.
Battery life Up to 5 years
Device testing To ensure proper functionality, the device must be tested at
least once every year by an installer.
Dimensions (transmitter) 19.00 mm x 104.80 mm
(0.75 in x 4.12 in)
Dimensions (magnet) 22 mm x 28 mm x 15 mm
(0.87 in x 1.10 in x 0.59 in)
Relative humidity 0% to 93%, non-condensing
Temperature (operating) Functional range: -10°C to +49°C (+14°F to +120°F)
EN 50130-5 Class II only: -10C to 40C (+14F to +104F)
Frequency 433.42 MHz
Table 8.13: Specifications