Notice!
The content in the graphical table applies to EN installations.
Reed switch settings
Set the detector to enable or disable the reed switch.
Notice!
Please note, insert the jumper onto the pin prior to installing the battery. Failure to do so may
result in unexpected operation of the device.
Callout ᅳ Description
1 ᅳ No jumper disables the internal reed switch
2 ᅳ Jumper on enables the internal reed switch
RADION inertia
The RFIN is a vibration detector combined with a wireless transceiver used for monitoring
doors or windows. Features include:
– A magnetic contact and external loop
– High and Low sensitivity settings
– Gross and Minor attack settings
– A cover and wall tamper switch
Maximum distance between
detector and magnet
<12.7 mm (1/2 in)
Place the magnet on either side of the detector.
Dimensions (transmitter) 22 mm x 91 mm x 35 mm
(0.87 in x 3.20 in x 1.38 in)
Dimensions (magnet) 22 mm x 28 mm x 15 mm
(0.87 in x 1.10 in x .59 in)
Power/voltage CR123A Lithium battery, 3 VDC ( )
Battery replacement One Duracell DL123A, or Panasonic CR123A, or Sanyo
CR123A. Check your battery yearly to ensure proper
functionality.
8.15.2
8.16
Easy Series Control Panel Device Specifications and Overview | en 97
Bosch Security Systems, Inc. System Reference Guide 2014.09 | 01 | F.01U.306.221