Account Number Entries Phone Number/IP Address Entries
Entry Key Press Entry Key Press
C [*][2] # [*][#]
D [*][3] . [*]
1
E [*][4] Pause [#]
F [*][5] Exit with Save [#][#]
2
Disable phone number [0][#]
Disable IP address 240.0.0.0
1
[*] = . between each IP address notation.
2
Press [#] twice within two seconds to exit without saving
your entry.
Outputs
Output devices consist of horns, bells, strobes, or sirens.
Outputs Enter an output number from 1 to 4
1 Set Output Function
Press [1] to select the current
option.
Press [2] to hear more options.
Press [#] to exit Output Function.
Output Functions:
Disabled
Intrusion
Intrusion Latching
Fire
Fire Latching
Intrusion and Fire
Intrusion and Fire
Latching
System Reset
Output Functions (cont.):
System On
System Ready
Key Fob On/Off
Key Fob 2-sec Pulse
User Controlled
Interior Intrusion and
Fire
System On (Unoccupied)
# Exit Points
Return to Installer Menu.
Notice!
When the installer PIN is entered at the keypad or phone, a 3 sec time window starts. During
that time window, a tamper alarm activates the interior siren for only 1 sec. Open the
enclosure door during this time to silence the sirens during maintenance. Once the enclosure
is closed, tamper alarm is restored after a 3 minute delay. Tampers are logged and reported.
!
Warning!
If you modify system parameters you are responsible for maintaining the system within the
scope of the standard and regulations that apply to the hardware and/or the system in which
it is used. In a NF A2P compliant installation, use only NF A2P listed components, and check
that each parameter is in the authorized range.