System Programming Items
Programming Item Item
Number
Selections Manuf.
Default
Country Code (refer to Country
Codes, page 111)
102 00 to 65 58
Enclosure Tamper Enabled 103 0 = Disabled
1 = Enabled
1
Fire Bell Cut-Off Time 107 0 to 90 min 5
Intrusion Bell-Cut off Time 108 0 to 90 min 5
Intrusion Abort Window 110 15 to 45 sec 30
Fire Alarm Cancel Window 111 0 to 10 min 0
Intrusion Cancel Window 112 5 to 10 min 5
Chime Tone Select 114 1 = Chime door bell
2 = Single chime
3 = Standard door bell
1
Chime Mode Operation After System
Off
115 0 = Off
1 = On
2 = Follows previous setting
0
Automatic Test Report Frequency 116 0 = None
1 = Daily
2 = Weekly
3 = Monthly
0
Access Code 119 6 digits, using 0 to 9 999999
Daylight Saving Time Operation 121 0 = None
1 = North America (before 2007)
2 = Europe and Asia
3 = Tasmania, Australia
4 = Rest of Australia
5 = New Zealand
6 = Cuba
7 = South America and Antarctica
8 = Namibia, Africa
9 = USA after 2006
1
Installer Passcode Override Enabled 122 0 = Disabled
1 = Enabled
1
Programming Key Auto Transfer 123 0 = Enable the programming key from the Installer
Menu.
1 = Programming key automatically sends or
receives stored programming data.
1
5.2.2
48 en | Programming Easy Series Control Panel
2014.09 | 01 | F.01U.306.221 System Reference Guide Bosch Security Systems, Inc.