Programming Item Item
Number
Selections Manuf.
Default
Point Alarm Verification 124 0 = None
1 = Cross zone
2 = Intelligent threat assessment
3 = Confirmed alarms 1
4 = Confirmed alarms 2
0
Faulted Points Allowed Threshold 125 0 to 8 3
Exit Delay 126 45 to 255 sec 60
Entry Delay 127 30 to 255 sec 30
Exit Time Restart 128 0 = User cannot reset Exit Delay timer
1 = User can reset Exit Delay timer one time
1
Recent Close Enabled 129 0 = Report not sent
1 = Report sent
1
Swinger Bypass Count 131 0-15 1
Auto Protection Level 132 0 = System turns on (unoccupied).
1 = System only turns on (unoccupied) if a
perimeter point is faulted during Exit Delay.
1
System On Order Options 133 1 = "Stay," "Leave," "Custom"
2 = "Stay," "Custom," "Leave"
3 = "Leave," "Stay," "Custom"
4 = "Leave," "Custom," "Stay"
5 = "Custom," "Leave," "Stay"
6 = "Custom," "Stay," "Leave";
1
Cross Zone Timer 134 60 to 3600 sec 120
Clear Alarm Memory 136 0 = By user, 1 = By master user 0
Latching Point and Enclosure
Tamper
137 0 = Any user can clear condition
1 = Only the installer can clear condition
0
Latching System Device Tamper 138 0 = Any user can clear condition
1 = Only the installer can clear condition
0
Verbose System Test Enabled 139 0 = Test results announced only at end of all tests
1 = Test results announced after each test
1
Demo Mode 140 0 = Telephone messages heard only on phone
1 = Telephone messages heard on phone and
control centers
2 = Turn announcement of telephone messages
over the control center on or off at the control
center
0
Restrict Installer Passcode 142 0 = Master user not needed
1 = Master user needed
0
Test Report Hour 143 0 to 23
Easy Series Control Panel Programming | en 49
Bosch Security Systems, Inc. System Reference Guide 2014.09 | 01 | F.01U.306.221