Programming Item Item Number NF A2P Approved
Range
Section Starting Page
Country Code 102 17 System Programming
Items, page 48
Enclosure Tamper Enabled 103 1
Fire Bell Cut-off Time 107 2 or 3
Intrusion Bell Cut-off Time 108 2 or 3
Intrusion Abort Window 110 0
Point Alarm Verification 124 0
Entry Delay 127 Shorter than Exit Delay
Auto Protection Level 132 0
Latching Point and Enclosure Tamper 137 1
Latching System Device Tamper 138 1
Restrict Installer Passcode 142 1
Start Arming With Faulted Points 159 0
Passcode Length 861 6 User Programming Items,
page 61
Circuit Style 9xx2* 0 Point Programming Items,
page 57
Response Time 9xx5* 4 or 5
* The middle digits = the point number. For example, "01" = Point 1, and "32" = Point 32.
Table 1.1: NF A2P Certified Configuration Values
Notice!
For supervised points (dual EOL), 2.2k Ω EOL resistors (P/N: 47819) required.
Seal the Enclosure
1. Open the pre-opened hole which is on the right of the enclosure.
2. Pass the sealing wire through this hole, and bring the two wires in the corresponding hole
of the enclosure door.
3. Seal the sealing lead as near as possible from the enclosure.