Event SIA Report Contact ID Report
RAM Checksum Failed YF Parameter Checksum Fail 1 303 RAM Checksum bad
Point Tamper TA Tamper Alarm 1 137 Tamper
Point Tamper Restoral TH Tamper Alarm Restoral 3 137 Tamper Restoral
Cross Zone Trouble BG Unverified Event - Burglary 1 378 Cross-zone Trouble
Cross Zone Trouble Restoral BR Burglary Restoral 3 378 Cross-zone Trouble
Point Missing UY Untyped Missing Trouble 1 381 Loss of Supervision - RF
Point Missing Restoral UJ Untyped Trouble Restore 3 381 Loss of Supervision - RF
Wireless Point Low Battery XT Transmitter Battery Trouble 1 384 RF Low Battery
Wireless Point Low Battery
Restoral
XR Transmitter Battery
Restoral
3 384 RF Low Battery
Wireless Receiver Jammed XQ RF Interference 1 344 RF Receiver Jam Detect
Wireless Receiver Jammed
Restoral
XH RF Interference Restoral 3 344 RF Receiver Jam Detect
Bus Device Tamper XS RF Receiver Tamper 1 341 Exp Module Tamper
Bus Device Tamper Restoral XJ RF Receiver Tamper
Restoral
3 341 Exp Module Tamper
Bus Device Trouble ET Expansion Trouble 1 330 System Peripheral Trouble
Bus Device Trouble Restoral ER Expansion Restoral 3 330 System Peripheral Trouble
Remote Programming Success RS Remote Program Success 1 628 Program mode exit
Remote Programming Failure RU Remote Program Fail 1 628 Program mode exit
24-Hour Trouble UA Untyped Zone Alarm 1 150 24-Hour Non-Burglary
24-Hour Trouble Restoral UR Untyped Zone Restoral 3 150 24-Hour Non-Burglary
Opening by Guard Code OR Disarm From Alarm 1 450 Exception Open/Close
System Inactive CI Fail to Close 1 454 Failed to Close
Network Fail NT Network Failure 1 350 Communication Trouble
Network Restoral NR Network Restoral 3 350 Communication Trouble
Passcode Tamper JA User Code Tamper 1 461 Wrong Code Entry
Firmware Updated YZ Service Completed 1 412 Successful Download/
Access
Watchdog Reset YW Watchdog Reset 1 305 System Reset
Date/Time Change JT Time Changed 1 625 Time/Date Reset
Easy Series Control Panel Control Panel Event Codes (SIA and Contact ID) | en 65