EasyManua.ls Logo

Bosch Solution 16i - Page 106

Bosch Solution 16i
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-16
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Comms Programming
Comms > MyAlarm > EMAiL
Email Address
-
MENU 5-5-8
Email
Address
1 Characters 80
i
Note
Email reporting requires rmware version 2.10 or
higher and will only operate within Australia.
This menu allows the installer or master user to program
the email address that the system will send reports to. The
email address can be programmed up to a maximum of
80 characters.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [5] + [5] + [8] + [OK].
The keypad will display the current email address.
_
3) Use the numeric, [0] to [9], [] and [] keys to enter
or change the email address as required.
At any time you can use the [] and [] keys to scroll
through the complete list of available characters.
To clear all characters from the cursor position to the
right, press the [OFF] key.
4) When the email address is complete, press [OK] to
save and exit, or press [MENU] to exit without saving.
5) To stop email reporting simply remove the email
address or disable all of the email options.
i
Note
When entering an email address the @ symbol is
represented on the keypad display as . To enter
this character continually press the 1 key until the
symbol appears.
Comms > MyAlarm > E-OPtS
Email Options
-
MENU 5-5-9
1 Open / Close Reports Y
2 Zone Alarm Reports Y
3 Zone Trouble Reports Y
4 System Reports Y
5 Access Events Y
6 Reserved N
7 Reserved N
8 Reserved N
i
Note
Email reporting requires rmware version 2.10 or
higher and will only operate within Australia.
This menu allows the master user to select which event
types will be reported using the email reporting function.
By default the rst 4 options are set to report via email.
Follow the procedure below to congure the required
options.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [5] + [5] + [9] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 2 3 4
3) Use the numeric keys [1] to [8] to turn on and o the
features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all email options are programmed, press [OK]
to save and exit, or press [MENU] to exit without
saving.
Open / Close Reports
This option allows the control panel to report open’ and
close’ reports via email.
Zone Alarm Reports
this option allows the control panel to report zone ‘alarm
and ‘restore’ reports via email.
Zone Trouble Reports
This option allows the control panel to report zone
‘trouble and restore reports via email when a user turns
on an area that has faulted zones.
System Reports
This option allows the control panel to report via email
numerous system reports (e.g. AC Fail, Low Battery etc)
via email.
Access Events
This option allows the control panel to report via email
when a valid token has been swiped or presented.