9-20
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Comms Programming
4) The keypad will display the rst six digits of the
Solution Link IP port number.
07701
5) Use the numeric keys [0] to [9] + [←] and [→] keys
to program the IP Address, then press [OK] to save
and exit or press [MENU] to exit without saving.
Comms > TCP/IP > L568
IP RAS Options
MENU 5-6-8
1 IP RAS Allowed Y
2 RAS Only If Disarmed N
3 Report Session Y
4 Report Lockout Y
5 UDP Installer RAS N
6 UDP User RAS N
7 Reserved N
8 Reserved N
This feature requires rmware version 2.10 or higher.
This menu allows the installer to select which IP options
are allowed.
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [6] + [8] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 3 4
3) Use the numeric keys [1] to [8] to turn on and o the
features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all email options are programmed, press [OK]
to save and exit, or press [MENU] to exit without
saving.
IP RAS Allowed
This option allows the control panel to connect with
Solution Link via the optional ethernet module.
RAS Only If Disarmed
This option allows a RAS connection via TCP IP
connection only when the system is disarmed.
Report Session
This option allows the control panel to report a RAS Start
and RAS End session to the security base station when a
remote TCP IP connection was made and ended.
Report Lockout
This option allows the control panel to report when the
maximum number of incorrect attempts has been made
to remotely connect to the panel using the IP connection
method.
UDP Installer RAS
This option allows the control panel to communicate
using the UDP internet protocol (User Datagram
Protocol) when the installer remotely connects via
Solution Link software.
If this option is not programmed, the control panel will
use the TCP IP protocol.
UDP User RAS
This option allows the control panel to communicate
using the UDP internet protocol (User Datagram
Protocol) when the user remotely connects via Solution
Link software.
If this option is not programmed, the control panel will
use the TCP IP protocol.
Comms > TCP/IP > L569
IP RAS Lockout Time
MENU 5-6-9
0 6 0
SECONDS
This feature requires rmware version 2.10 or higher.
This menu allows the control panel to lockout and prevent
the ability for anyone to remotely connect to the system
using the RAS IP connection method. During the lockout
time, (1 to 255 seconds / 0 = No Lockout), the system
will not respond to any TCP IP connection requests. The
lockout count is set at 6 failed attempts (xed) over a 60
second period)
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [6] + [9] + [OK]. The keypad will display
the current IP RAS Lockout time.
d= 060