9-21
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Comms Programming
3) Using the numeric keys, enter the new IP RAS
Lockout Time, then press [OK] to save and exit or
press [MENU] to exit without saving. Valid entires
are 0 to 255 seconds.
CO MM S T ES TI NG
Comms > Comms Test > tst-d
Send Test Report
-
-
MENU 5-9-0
This menu allows you to test the reporting functions of
the control panel by manually sending a ‘Test’ report to
the receiving party (i.e. security company monitoring
station, mobile telephone etc).
1) Enter your PIN + [MENU].
2) Enter [5] + [9] + [0] + [OK].
The test will begin and the keypad will display that
testing is in the progress. The test may take up to 3
minutes to complete.
ph tst
If the test is successful, the keypad will prompt:
pAss
If the test is NOT successful, the keypad will prompt:
fAil
3) Press [OK] or [MENU] to exit.
Comms > Comms Test > L591
Test Report Time
MENU 5-9-1
Test Time
0 2 : 0 0
H H : M M
This menu programs the time of the day that the panel
will send the automatic Test Report to the base station
receiver. Automatic test reports are used to verify the
panels ability to report events via the telephone line on
an ongoing basis.
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [9] + [1] + [OK]. The keypad will display
the current hour of the day that the test report is
set.
hh =02
3) Use the numeric keys to hour of the day that the
test report is required. The keypad display the
current minute of the day that the test report is set.
hh =02
4) Use the numeric keys to program the minutes of
the hour that the test report is required.
5) Press [OK] to save and exit or press [MENU] to exit
without saving.
The time set should be entered using the 24-hour
format.
Comms > Comms Test > L592
Test Report Period
MENU 5-9-2
(*** System Wide Parameter ***)
0 1
00 = No Test Report 08 = Reserved
01 = Every Day 09 = Reserved
02 = Every Week 10 = Reserved
03 = Every Month 11 = Reserved
04 = Reserved 12 = Reserved
05 = Reserved 13 = Reserved
06 = Reserved 14 = Every Hour
07 = Reserved 15 = Every 12 Hours
Options 14 and 15 are only available from rmware
revision 2.10 or higher.
This menu programs how often the control panel will
send a test report. Only one option can be programmed.
(*** System Wide Parameter ***)
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [9] + [2] + [OK]. The keypad will display
the current Test Report Period.
d= 1
3) Use the numeric keys to enter the Test Report
Period, then press [OK] to save and exit or press
[MENU] to exit without saving.