10-1
Bosch Security Systems 09/11 BLCC500I
S E C T IO N 10
Device Programming
T
his chapter covers the dierent device types and the
numerous programmable options which can be used
to control how a device operates.
The commands menu allows you to view the status of any
device in the system and will display its condition as well
as the temperature and voltage where available.
Keypads are the most common device used in the system
and must be assigned to a home area if they are to operate
correctly in a system. You are also able to set the contrast,
backlight and beeper volume to your own personal
preference.
RF Devices can also be connected to the system and from
this menu you are able to set supervision times, receiver
jamming, tamper options and more.
D EV IC E CO MM AN D S
Devices > Commands > LAN-St
LAN Status
-
-
MENU 6-0-0
This menu provides a listing of all devices and modules
connected to your system. Using this option it is possible
to view the voltage, temperature and other information
about each of the modules.
1) Enter your PIN + [MENU].
2) Enter [MENU] + [6] + [0] + [0] +[OK].
The keypad will display the rst device tted to the
system.
3) Use the [↑] and [↓] keys to select the device that you
want to view, then press [OK] to select.
cP001
The system display CP001 which represents Keypad
number 1 on the system. Press [OK[ to view.
The display will show each parameter for the device
one at a time.
Display shows the
current keypad
temperature.
t=22c
Displays the current
voltage being
measured at the
keypad.
v=13-8
Displays the rmware
version of the keypad.
r=1-00
Displays the keypad
size. 8 Zone or
16 Zone
16 Zn
Displays if the keypad
has an in built
proximity reader.
pro
4) Press [OK] or [MENU] to exit.
Devices > Commands > L601
LAN Secure
MENU 6-0-1
If the LAN network is secure, this will prevent the system
detecting additional LAN devices when the system has
been powered down, additional devices connected and
powered back up again. If the LAN network is not secured,
the system will automatically detect any additional
devices added when the system has been powered down
and then powered back up again.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [0] + [1] + [OK]. If the system LAN is not
secured, the keypad will display the following.
SecOff