10-9
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Device Programming
E TH ERN ET D EV I CE O P TI ON S
Devices > Ethernet > L660
IP Address Module
-
MENU 6-6-0
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
i
Note
This feature requires rmware version 2.10 or higher.
This is the IP address of the TCP/IP module on the
customers internal local area network.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [6] + [0] + [OK]. The keypad will display
the rst 6 digits of the current IP address.
000000
3) Use the numeric keys [0] to [9] + [] and [] keys
to program the IP Address, then press [OK] to save
and exit or press [MENU] to exit without saving.
Devices > Ethernet > L661
Subnet Mask
-
MENU 6-6-1
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
i
Note
This feature requires rmware version 2.10 or higher.
The can be found by running IPCONFIG on a PC
connected to the clients network. Typical subnet mask is
255.255.255.0.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [6] + [1] + [OK]. The keypad will display
the rst 6 digits of the current subnet mask.
000000
3) Use the numeric keys [0] to [9] + [] and [] keys
to program the 12 digit subnet mask number, then
press [OK] to save and exit or press [MENU] to exit
without saving.
Devices > Ethernet > L662
Default Gateway
-
MENU 6-6-2
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
i
Note
This feature requires rmware version 2.10 or higher.
The can be found by running IPCONFIG on a PC connected
to the clients network.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [6] + [2] + [OK]. The keypad will display
the rst 6 digits of the current gateway number.
000000
3) Use the numeric keys [0] to [9] + [] and [] keys
to program the 12 digit gateway number, then
press [OK] to save and exit or press [MENU] to exit
without saving.
Devices > Ethernet > L663
MAC Address
MENU 6-6-3
0 0 0 0 0 0 0 0 0 0 0 0
i
Note
This feature requires rmware version 2.10 or higher.
This is the hardware machine address of the module and
can be found on the bar-coded sticker.
1) Enter your Installer PIN + [MENU].
2) Enter [6] + [6] + [3] + [OK]. The keypad will display
the rst 6 digits of the current MAC address.
000000
3) Use the numeric keys [0] to [9] + [] and [] keys
to program the MAC address, then press [OK] to
save and exit or press [MENU] to exit without
saving. This is the hardware machine address of the
module and can be found on the bar-coded sticker.