5-10
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Access Programming
Access > Prox Reader > L161
Area Assignment
MENU 1-6-1
1 Area 1 Y
2 Area 2 N
3 Area 3 N
4 Area 4 N
This menu programs which area (1 to 4) the reader will
operate. Each reader can assigned to operate a single area.
Software version 2.10 and higher now allow
proximity readers to be assigned to multiple areas.
When using a prox keypad reader, if you set the area
assignment to a specic area number then only that area
will arm / disarm when a valid token is used.
If you set the area assignment to 0 (zero), and a token
is presented then the keypad will move to the rst
area which that user has access to. If the same token is
presented a second time then the area currenttly in focus
will arm or disarm.
If the user wants to arm / disarm a dierent area which
they have access to, then after swiping their token the rst
time, they can use the left and right arrow keys to move to
the desired area and then swipe their token a second time
to operate.
If the user wants to arm / disarm all areas they belong to,
then after swiping their token once, they can press and
hold the [ON] key to arm or the [OFF] key to disarm all
areas they belong to.
1) Enter your Installer PIN + [MENU].
2) Enter [1] + [6] + [1] + [OK].
3) Enter the Reader required, then press [OK].
4) Use keys [1] to [4] to toggle on or o the required
area (s), then press [OK] to save and exit or press
[MENU] to exit without saving.
-Bit-
1 2 4
The keypad display will return back to its home area
if no keys are pressed or tokens are presented for 60
seconds.
Access > Prox Reader > L162
Access Assignment
MENU 1-6-2
1 Access Group 1 N
2 Access Group 2 N
3 Access Group 3 N
4 Access Group 4 N
5 Access Group 5 N
6 Access Group 6 N
7 Access Group 7 N
8 Access Group 8 N
This menu is used to assign a Prox Reader to one or more
Access Groups (1 to 8). Access Groups are used to restrict
user access to doors.
Setting this option to 0 means the reader will not operate
any system outputs.
1) Entery your Installer PIN + [MENU].
2) Enter [1] + [6] + [2] + [OK].
3) Enter the Reader required, then press [OK].
4) Use keys [1] to [8] to toggle on or o the required
access groups.
-bit-
5) Press [OK] to save and exit or press [MENU] to exit
without saving.
Access > Prox Reader > L163
Reader Options
MENU 1-6-3
1 All On Arming Allowed Y
2 Disarming Allowed Y
3 Badging Required N
4 Zero Exit Time N
5 Part On Arming Allowed N
6 Arm If Single User Area N
7 Reserved N
8 Arm All User Areas N
1) Enter your Installer PIN + [MENU].
2) Enter [1] + [6] + [3] + [OK].
3) Enter the Reader required, then press [OK].
4) Use keys [1] to [8] to toggle on or o the required
reader options.