9-6
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Comms Programming
d= 06
3) Using the numeric keys, enter the required number
of call attempts per destination. Valid entries are 1
to 15. 0 = reporting disabled.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Setting the Call Attempt count to zero will disable all
reporting for Detination 1 and Destination 2
Comms > Properties > L521
Dialler Options
MENU 5-2-1
1 Dialler Enabled Y
2 Pulse Dialling N
3 Dial Tone Detect Y
4 Busy Tone Detect N
5 Mirror Reports To Web Y
6 Extend Handshake Wait Period To 1 Minute N
7 Reserved N
8 Abort Failed Reports Y
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [2] + [1] + [OK]. The keypad will display
the current Dialler Options.
-Bit-
1 3 5 8
3) Use the numeric keys [1] to [8] to toggle on or o
the option required.
4) Repeat Step 3 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Dialler Enabled
This option enables the dialler reporting function. When
disabled, all dialler reporting will stop.
Pulse Dialling
This option will congure the panel to use pulse or
decadic dialling rather than tone or DTMF dialling. DTMF
dialling should always be used unless the telephone
network you are communicating on does not support it.
Dial Tone Detect
This option congures the panel to start dialling as soon
as it detects dial tone on the line. This can speed up the
dialing process by up to 3 seconds. If no tone is detected
the panel will blind dial after 4 seconds.
If this option is disabled the panel will blind dial.
Busy Tone Detect
This option congures the panel to detect busy tone. If a
busy tone is detected during the dialling sequence, the
panel will immediatly hang up and move on to the next
number in the sequence in an attempt to get the report
through as quickly as possible.
If this option is disabled, the panel will wait for a period
of 30 seconds before dialling the next telephone number
in the sequence. The 30 second timer starts when the
rst digit of the rst telephone number is dialled.
Mirror Reporting To WEB Email
Reserved.
Extend Handshake Wait Period To 1 Minute
This option sets the panel to wait for up to 60 seconds
to receive a valid handshake signal from the base station
receiver. The handshake tone indicates to the panel
that it has reached the security company’s base station
receiver and can now send it’s pending reports.
If this option is disabled the handshake wait time will
default to 30 seconds.
Abort Failled Reports
Setting this option will cause a failled report to be
agged in the log and no further reports will be made for
that event.
A report will be failled if the number of programmed
dial attempts has been reached .
Comms > Properties > L522
Phone Line Options
MENU 5-2-2
1 Display Telephone Line Fail Y
2 Report Telephone Line Fail Y
3 Alarm On Line Fail If Armed N
4 Alarm On Line Fail If Disarmed N
5 Reserved N
6 Reserved N
7 Reserved N
8 Display Phone In Use N
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [2] + [2] + [OK]. The keypad will display
the current Phone Line Options.
-Bit-
1 2