9E-926 42 SmartControl™ Meter & TouchPoint™
Operation Instructions
Table 4: Milking Parameters
Function Unit Min.
Value
Max.
Value
Default
Value
Increment
Value
Comments
Take Off Flow Rate Pounds/Minute
(Grams)
0.2
(100)
3.0
(1500)
1.0
(500)
0.1
(10)
Take Off Delay Seconds 0.0 20 0.5 0.1
Vacuum On Delay Seconds 0.0 9.9 0.1 0.1
Let-Down Delay Seconds 60 250 120 1
Reattach Let-Down
Delay
Seconds 30 250 60 1
Maximum Milking
Time
Minutes 0.0 25.5 0.0 0.1 0 turns off
Retract Delay Seconds 0.0 3.5 0.8 0.1
Claw Drop Delay Seconds 3 20 0 1 0 turns off
Claw Lift Timeout Minutes 0.0 20 0 1 0 turns off
Claw Lift Group Size Seconds 1 255 0 1 0 turns off
Maximum Manual
Time
Seconds 0.0 200 0 1 0 turns off
Manual Milk Time Seconds 0.0 200 0 1 0 turns off
Milk Sweep Delay Seconds 0.0 10 0.0 0.1
Milk Sweep On Time Seconds 0.0 10 0.0 0.1
Pre-Wash 0 0 1 turns on
System Adjustment
Factor
Percent -10.0 10.0 0.0 0.1