SmartControl™ Meter & TouchPoint™ 43 9E-926
Operation Instructions
Table 5: Pulsation
Function Parameter
Min
Value
Max
Value
Default
Value
Increment
Value
Comments
Pulsation Rate-
Cow
Pulses per min-
ute
45 65 0 1 Only Aux outputs 3
and 4 can be used for
pulsation.
Front Ratio On
Time
Percent 50 70 60 1 Aux 3 output is front
Rear Ratio On
Time
Percent 55 70 60 1 Aux 4 output is rear
Pulsation Start
Delay
Seconds 0 20 0 1 0 turns off delay
Pulsation (Both)
Pulsation can only be used with BouMatic pulsators for parlors
that require individual stall pulsation.
Pulsation Rate (Both)
The Pulsation Rate is the number of times the pulsators will
turn on and off per minute.
Front Ratio On Time (Both)
The Front Ratio On Time is set with the conguration software.
The on times for the front and rear are automatically offset
regardless of settings.
Rear Ratio On Time (Both)
The Rear Ratio On Time is set with the conguration software.
The on times for the front and rear are automatically offset
regardless of settings.
Pulsation Start Delay (Both)
The Pulsation Start Delay is the time that both the front and
rear liners are at maximum diameter during the attach se-
quence. After the Start Delay, pulsation will be set to the pul-
sation rate and ratio.