45-2 THV TUNE UP
This mode shall be used when the transfer voltage needs to be adjusted due to errors
such as transfer failure onto the media. The adjustment is used to change the transfer
voltage, subject to the media to be used, against the reference value 0 (zero) in the range
-4 to +4.
Note: Do not perform this mode frequently.
Description of Procedures LCD Message
1) Press the Continue button after selecting
Screen (a) “NVM TUNE UP”.(a)
→
(b)
2) After selecting THV TUNE UP Code 2, press
the Continue button. (b)
→
(c)
3) After selecting the media to be adjusted,
press the Continue button. (Ex. PPC).
(c)
→
(d)
4) Adjustment can be made in 8 steps between
-4 and +4.
After selecting a given number, press the
Continue button. (d)
5) Press the Font button to finish the adjustment
for PPC. (d)
→
(e)
Repeat steps 3 to 5 for other media such as
OHP or Labels.
6) Press the Font button to finish the
adjustments. (e)
→
(f)
39 FACTORY MODE
NVM TUNE UP
45 NVM TUNE UP
45 THV TUNE UP
PPC/OHP/LABEL