VII-45
Fig.7-76
PRECAUTION
Do not touch the surface of the heater lamp with your hands, the small traces of oil
you leave on the lamp will affect the life of the lamp.
The wattage and length of the heater lamp is different between the fuser roller and the
back-up roller. The wattage is marked on the insulator of the lamp electrode.
Fuser roller: 400W (Length;342mm)
Back-up roller : 300W (Length;332mm)
Note:
When installing the new fusing unit into the printer, you have to wait approximately for 30
minutes after the unit is installed to allow the fusing oil to circulate in the unit.
Fuser Lamp (300W)
Terminal (L)
Fuser roller
Fuser Lamp (400W)
Terminal (L)
Back-up roller
PR98311