VIII-32
Error Code
Concerned Part
Fan Motor(Control Cooling)
F0
Check the connection of the fan motor connector.
Is DCN13 of IOD1 properly connected to the fan motor ?
Is DCN1 of IOD1 properly connected with 11CN of MCTL PCB ?
Is the voltage between DCN13-1 and 2 a trailing edge ?
Is the voltage between DCN1-47 and 1 a trailing edge ?
Is F0 error cleared ?
Finished.
Is F0 error cleared ?
Connect them properly.
Replace the MCTL PCB.
MCTL
11CN
1
47
PGND
CTFANON-P
IOD1
DCN1
DCN13
CTL
FAN
YES
NO
YES
NO
YES
NO
1
47
CTFANON-P
PGND
CTFANERR
NO
Replace the fan motor.
Replace the IOD1 PCB.
YES
YES
NO
1
2
3
Control Fan
Check the voltage (CTFANON-P)
Finished.