EasyManua.ls Logo

Brother HL-2400C - Page 282

Brother HL-2400C
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VIII-36
Error Code
Concerned Part
Fusing Unit
Check the connection of the fusing unit connector.
Is the fusing unit properly installed ?
Is there any contact failure due to damaged to the fusing unit connector ?
Are the connectors connected between the fusing unit
and BCN2 of the high voltage unit (HVU) OK ?
Replace the fusing unit.
Is H0 error cleared ?
Is H0 error cleared ?
Re-install the fusing unit.
MCTL
11CN
42
44
TH1
TH2
IOD1
DCN1
DCN14
HVU
YES
NO
YES
42
44
TH1
TH2
NO
Replace the IOD1 or MCTL PCB.
BCN2
TH2
TH1
NO
Replace the charger unit or belt cartridge.
Connect them properly.
16
18
16
18
Fusing Unit
Fuser Connector
NO
YES
1
2
3
4
H0 (wire cut/ short error of thermistor)
Finished.
Finished.

Table of Contents

Related product manuals