2-63
Confidential
■ Error code C1 to C6
These errors do not usually occur in the normal use. The conceivable causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
Error, which cannot be specified, occurs.
■ Error code C7
Insufficient memory.
■ Error code C8
RAM area for secure data full.
---
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Out of Memory
Press Job Cancel.
<User Check>
• Delete the stored data.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Out of Memory
Secure Print Data is full. Press Job Cancel and delete the
previously stored data.
<User Check>
• Delete the stored data.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.