2-80
Confidential
■ Error code B000
The first or second side CIS flat cable was detected to be not inserted correctly.
■ Error code BB00
The white level value obtained with function code 55 was outside the specified range.
SCANNER ERROR FB / SCANNER ERROR ADF
-
Step Cause Remedy
1 Connection failure of the first
side CIS flat cable
Reconnect the first side CIS flat cable.
2 Connection failure of the second
side CIS flat cable
Reconnect the second side CIS flat cable.
3 First side CIS flat cable damaged Replace the first side CIS flat cable.
4 Second side CIS flat cable
damaged
Replace the second side CIS flat cable.
5 First side CIS unit failure Replace the first side CIS unit.
6 Second side CIS unit failure Replace the second side CIS unit.
7 Main PCB failure Replace the main PCB ASSY.
Scanner Error BB
-
Step Cause Remedy
1 First side or second side CIS unit
calibration data error
Perform “Function code 55”.
(Refer to
“1.3.19 Acquisition of white level
data and setting of CIS scanning area
(Function code 55)” in this chapter
.)
2 First side CIS flat cable damaged Replace the first side CIS flat cable.
3 Second side CIS flat cable
damaged
Replace the second side CIS flat cable.
4 First side CIS unit failure Replace the first side CIS unit.
5 Second side CIS unit failure Replace the second side CIS unit.