2-53
Confidential
â– Error code 6001
The front cover sensor detected that the front cover was open.
< User Check >
- Close the front cover.
â– Error code 6004
The eject sensor detected that the fuser cover was open.
< User Check >
- Close the fuser cover.
Cover is Open
Close the Front Cover.
Step Cause Remedy
1 Connection failure of the front
cover sensor harness
Reconnect the front cover sensor
harness.
2 Front cover failure Replace the front cover.
3 Front cover sensor failure Replace the front cover sensor.
4 Main PCB failure Replace the main PCB ASSY.
Cover is Open
Close the Back Cover of the machine.
Step Cause Remedy
1 Eject actuator that has come off
or that has been caught
Re-assemble the eject actuator.
2 Fuser cover installation failure Re-assemble the fuser cover.
3 Connection failure of the eject
sensor PCB harness
Reconnect the eject sensor PCB harness.
4 Eject sensor PCB failure Replace the eject sensor PCB ASSY.
5 Main PCB failure Replace the main PCB ASSY.