Functions and parameters
Parameters
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT Repair Manual RRE140/160/180/200/250 4 – 73
383 10 15000 10 10 mm Lift height limitation 4
384 10 15000 10 10 mm Lift height limitation 5
385 10 15000 10 10 mm Lift height limitation 6
386 10 15000 10 10 mm Lift height limitation 7
387 0 2 1 0 Lift height limitation 1, function selection
0 = deactivated
1 = Can be overridden
2 = Cannot be overridden
388 0 2 1 0 Height limitation 2, function selection, see
387
389 0 2 1 0 Height limitation 3, function selection, see
387
390 0 2 1 0 Height limitation 4, function selection, see
387
391 0 2 1 0 Height limitation 5, function selection, see
387
392 0 2 1 0 Height limitation 6, function selection, see
387
393 0 2 1 0 Height limitation 7, function selection, see
387
394 0 2 1 0 Height limitation 8, function selection, see
387
395 0 15000 10 0 mm Height limitation 1 controlled by external sig-
nal
0 = deactivates the limit
396 0 15000 10 0 mm Height limitation 2 controlled by external sig-
nal
0 = deactivates the limit
397 0 15000 10 0 mm Height limitation 3 controlled by external sig-
nal
0 = deactivates the limit
CID1 parameters
501 0 0 1 0 Display illumination
503 0 8 1 3 Operator access
1, 2 = Key/button (controlled from the MCU)
3, 4 = Keypad using 100 PIN codes
5, 6 = Keypad using DHU
7, 8 = ID unit
Odd number = Access to operator parameter
Even number = No access to operator
parameter
No. Min. Max. In-
cre-
ment
De-
fault
Unit Description

Table of Contents