For example:
Maximum DS Train Rate Minimum DS Shapeable Rate
50M 1.5M
40M 1.2M
30M 900K
20M 600K
10M 300K
5M 150K
1.5M 45K
Note: If the CIR/PIR is lower than the minimum-
it is not enforced; downstream traffic is allowed up to the
minimum rate.
Parameters
You can provision the following parameters for Ethernet bandwidth profiles:
Parameter Description Valid Options
Name* Name of the bandwidth profile.
Committed Rate
for Upstream
Committed information rate for upstream tr
affic. Where rates may be
specified as follows:
In 64 kbps increments up to 2 Mbps
In 1 Mbps increments between 2 Mbps to 1000 Mbps
0 kbps disables the meter
Use "m" suffix for Mb/s or "g" for Gb/s in whole number increments.
0-2048kpbs, 0-
1000Mbps, 1Gbps
kbps in 64k increments
Peak Rate for
Upstream
Peak information rate for upstream traffic. Where rates may be
specified as follows:
In 64 kbps increments up to 2 Mbps
In 1 Mbps increments between 2 Mbps to 1000 Mbps
0 kbps disables the meter
Use "m" suffix for Mbps or "g" for Gbps in whole number increments.
0-2048kpbs, 0-
1000Mbps, 1Gbps
kbps in 64k increments
Peak Rate for
Downstream
Peak information rate for downstream traffic. Where rates may be
specified as follows:
In 64 kbps increments up to 2 Mbps
In 1 Mbps increments between 2 Mbps to 1000 Mbps
0 kbps disables the meter
Use "m" suffix for Mbps or "g" for Gbps in whole number increments.
0-2048kpbs, 0-
1000Mbps, 1Gbps
kbps in 64k increments
Downstream Peak
Burst Size
Peak burst size for downstream traffic.
Use "k" suffix for Kbytes (4 to 16000kbps)
Use "m" suffix for Mbps (0 to 16 mbps)
Use whole number increments