outlet must be used for this unit.
DO NOT plug another appliance or
charger into the same outlet.If the
electrical circuit capacity is not
enough or there is a defect in the e
lectrical work, it can lead to shock,
re, unit and property damage.
DO NOT modify the length of the
power cord or use an extension cord.
DO NOT connect the unit with the
power source until all wiring and
piping is completed.
7
GB-15
7. WIRING
7.1 Safety Precautions
WARNING
Be sure to disconnect the power
supply before working on the unit.
All electrical wiring must be done
according to local and national
regulations.
Electrical wiring must be done by a
qualified technician. Improper
connections may cause electrical
malfunction, injury and re.
An independent circuit and single
Connect the power cable to the
terminalsand fasten it with a clamp.
An insecure connection may cause
re.
Make sure that all wiring is done
correctly and the control board cover
is properly installed. Failure to do so
can cause overheating at the
connection points, re, and electrical
shock.
Ensure that main supply connection
is made through a switch that
disconnects all poles, with contact
gap of a least 3mm (0.118”).
CAUTION
Connect the outdoor wires before
connecting theindoor wires.
Make sure you ground the unit. The
grounding wire should be away from
gas pipes, water pipes, lightning rods,
telephone or other grounding wires.
Improper grounding may cause
electrical shock.
Make sure that you do not cross your
electrical wiring with your signal
wiring, as this can cause distortion
and interference.
Follow these instructions to prevent
distortion when the compressor starts:
The unit must be connected to the main
outlet. Normally, the power supply must
have a low output impedance of 32
ohms.
No other equipment should be
connected to the same power circuit.
The unit’s power information can be
found on the rating sticker on the
product.
7.2 Outdoor Unit Wiring
WARNING
Before performing any electrical or wiring
work, turn off the main power to the system.
1. Prepare the cable for connection
a. You must rst choose the right cable
size before preparing it for connection.
Be sure to use H07RN-F cables.

Table of Contents

Other manuals for Carrier 42QHC009D8S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 42QHC009D8S Series and is the answer not in the manual?

Carrier 42QHC009D8S Series Specifications

General IconGeneral
BrandCarrier
Model42QHC009D8S Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals