outlet must be used for this unit. 
DO NOT plug another appliance or 
charger into the same outlet.If the 
electrical circuit capacity is not 
enough or there is a defect in the e
lectrical work, it can lead to shock, 
fire, unit and property damage.     
DO NOT modify the length of the 
power cord or use an extension cord. 
DO NOT connect the unit with the 
power source until all wiring and 
piping is completed.
7
GB-15
7. WIRING
7.1 Safety Precautions
 WARNING
•  Be sure to disconnect the power  
supply before working on the unit. 
•  All electrical wiring must be done 
according to local and national 
regulations. 
•  Electrical wiring must be done by a 
qualified technician. Improper 
connections may cause electrical 
malfunction, injury and fire. 
•  An independent circuit and single 
 
•  Connect the power cable to the  
terminalsand fasten it with a clamp. 
An insecure connection may cause 
fire. 
•  Make sure that all wiring is done  
correctly and the control board cover 
is properly installed. Failure to do so 
can cause overheating at the 
connection points, fire, and electrical 
shock.  
•  Ensure that main supply connection 
 
is made through a switch that 
disconnects all poles, with contact 
gap of a least 3mm (0.118”). 
• 
 
 CAUTION
•  Connect the outdoor wires before 
connecting theindoor wires.
•  Make sure you ground the unit. The 
grounding wire should be away from 
gas pipes, water pipes, lightning rods, 
telephone or other grounding wires. 
Improper grounding may cause 
electrical shock.    
• 
•  Make sure that you do not cross your 
electrical wiring with your signal 
wiring, as this can cause distortion 
and interference.  
Follow these instructions to prevent 
distortion when the compressor starts: 
 •  The unit must be connected to the main 
outlet. Normally, the power supply must 
have a low output impedance of 32 
ohms.  
•  No other equipment should be 
connected to the same power circuit.
•  The unit’s power information can be 
found on the rating sticker on the 
product. 
7.2 Outdoor Unit Wiring
 WARNING
Before performing any electrical or wiring 
work, turn off the main power to the system. 
1. Prepare the cable for connection
a. You must first choose the right cable 
size before preparing it for connection. 
Be sure to use H07RN-F cables.