43
ENCODER KNOB - A
Adjust the value of the parameter WELDING CURRENT (
).
In this case the values displayed become those pre-set.
After a period of 3 seconds the values displayed go back to those measured if possible.
PARAMETER DISPLAY S
CREEN - V
Shows the value (measured, if possible) for the parameter indicated by the PARAMETER
SELECTION LED - V.
PARAMETER SELECTION LED - V
The LED unit indicates the welding parameter selected using the PARAMETER SELECTION K
EY
- V.
PARAMETER SELECTION K
EY - V
Scrolls in succession the parameters HOT START (
) - WELDING VOLTAGE ( ) - ARC
FORCE (
) only on the HT4 panel.
ENCODER K
NOB - V
Scrolls in succession the parameters HOT START (
) - ARC FORCE ( ).
SPECIAL FUNCTIONS (F
X) KEY
Only enables entering and exit afterwards from the SPECIAL FUNCTIONS Menu (SET UP
Fx) on the HT4 panel and not on the DH panel.
5 - HOLD MMA
When welding ends the fields in the display must show the same values that were displayed during welding, with the difference
that they are now values defined as HOLD. In this phase the VISION S
CREEN
shows the HOLD box highlighted, while on the HT4
panel the HOLD FUNCTION LED flashes until the end of the HOLD Function. If the HOLD Function is Interrupted via a panel (e.g. DH),
it will also be interrupted automatically on the other (HT4) and vice-versa.
“DH” CONTROL PANEL
AV
68 7.2
MMA Cr Ni
PROGRAM 3200
VRD ACTIVE
MENU KEY ENTER/MEM KEY
ENCODER KNOB - SX ENCODER KNOB - DX
VISION SCREEN
SX KEY DX KEY
MENU KEY
Used to access the PROCESS SELECTION Menu (PROCESS) interrupting the HOLD
Function and subsequent menus, as applicable.
ENCODER K
NOB - SX
Adjusts the WELDING CURRENT (
) parameter, interrupting the HOLD Function.
ENTER/MEM K
EY
If held down for 3 consecutive seconds, it interrupts the HOLD Function and makes it
possible to access SAVE JOB.
DX K
EY
Scrolls in succession WELDING VOLTAGE ( ) - HOT START ( ) - ARC FORCE ( ) only
on the VISION S
CREEN (the operation is activated when the key is released).
In this case the values displayed are those for HOLD (only for the welding voltage).
ENCODER K
NOB - DX Adjusts the parameter selected using the DX KEY interrupting the HOLD Function.