Appendix A Power Supply Specifications
6000 W AC-Input Power Supply
6000 W Power Supply AC Power Cords
Table A-18 lists the specifications for the AC power cords that are available for the 6000 W AC-input
power supply. Included in the table are references to illustrations of the power cords.
Front panel LEDs
• INPUT OK 1 and INPUT OK 2 • Green—Source voltage is OK. (Input voltage is
85 VAC or greater.)
• Off—Source AC voltage falls below 70 VAC, is
not present, or the power supply is turned off.
• FAN OK • Green—Power supply fan is operating properly.
• Off—Power supply fan failure is detected.
• OUTPUT FAIL • Red—Problem with one or more of the DC-output
voltages of the power supply.
• Off—DC-output voltages within acceptable
margins.
Weight 25.4 lb (11.5 kg)
1. The power supply is limited to 4000 W when installed in a Catalyst 6506, Catalyst 6509, and Catalyst 6509-NEB chassis.
Table A-19 6000 W AC-Input Power Supply Specifications (continued)
Specification Description
Table A-20 6000 W Power Supply AC Power Cords
Locale
Power Cord
Part Number Source Plug Type Cordset Rating
Power Cord
Reference
Illustration
Australia, New Zealand CAB-AC-16A-AUS= AU20S3 16 A, 250 VAC Figure A-43
People’s Republic of
China
CAB-AC16A-CH= GB16C 16 A, 250 VAC Figure A-34
Continental Europe CAB-AC-2500W-EU= CEE 7/7 16 A, 250 VAC Figure A-38
International CAB-AC-2500W-INT= IEC 309 16 A, 250 VAC Figure A-39
Israel CAB-AC-2500W-ISRL= SI16S3 16 A, 250 VAC Figure A-31
Japan, North America
(nonlocking plug)
200–240VAC operation