For a deeper understanding of these fields, refer to Request for Comments (RFC) 3261.Note
SIP Parameters
Table 27: SIP Parameters Settings
DescriptionField
The maximum times a call can be forwarded. The
valid range is from 1 to 255.
Default setting: 70
Max Forward:
Number of times an invite can be redirected to avoid
an infinite loop.
Default setting: 5.
Max Redirection:
The maximum number of times (from 0 to 255) a
request may be challenged.
Default setting: 2
Max Auth:
The User-Agent header used in outbound requests. If
empty, the header is not included. Macro expansion
of $A to $D corresponding to GPP_A to GPP_D
allowed.
Default setting: $VERSION
SIP User Agent Name:
The server header used in responses to inbound
responses.
Default setting: $VERSION
SIP Server Name:
The User-Agent name to be used in a REGISTER
request. If this value is not specified, the SIP User
Agent Name parameter is also used for the
REGISTER request.
Default setting: Blank
SIP Reg User Agent Name:
Defines the SIP Reg message Sequence Number.
Default setting: Blank
SIP Reg Starting Sequence Number:
Accept-Language header used. There is no default;
this indicates that the ATA does not include this
header. If empty, the header is not included.
Default setting: Blank
SIP Accept Language:
Cisco ATA 191 and ATA 192 Analog Telephone Adapter Administration Guide for Multiplatform Firmware
37
Voice Settings Configuration
SIP Parameters

Table of Contents

Other manuals for Cisco ATA 192

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ATA 192 and is the answer not in the manual?

Cisco ATA 192 Specifications

General IconGeneral
Ports2 FXS ports
Network Interface10/100 Ethernet
Voice ProtocolSIP
Audio CodecsG.711, G.726, G.729
Operating Temperature0 to 40°C (32 to 104°F)
Storage Temperature-20 to 60°C (-4 to 140°F)
Humidity10 to 90% non-condensing
ComplianceFCC, CE, UL