DescriptionField
The ATA supports bell 202 and v.23 standards for
caller ID generation. Default setting: bell 202
Caller ID FSK Standard:
Select the method you want to use, Default, or
Sweden default. Default setting: Default.
Feature Invocation Method:
Line 1 and Line 2 Settings (PHONE 1 and PHONE 2)
Use the Voice > Line 1 and Voice > Line 2 pages to configure the settings for calls through the PHONE 1
and PHONE 2 ports.
Enter the settings as described. After making changes, click Submit to save your settings, or click Cancel to
redisplay the page with the saved settings.
In a configuration profile, the FXS parameters must include an appropriate numeral for identifying the
port receiving the setting.
Note
General
Table 47: General Settings
DescriptionField
To enable this line for service, select yes. Otherwise, select no.
Default setting: yes
Line Enable
Streaming Audio Server (SAS)
Table 48: Streaming Audio Server Settings
DescriptionField
To enable the use of the line as a streaming audio source, select yes.
Otherwise, select no. If enabled, the line cannot be used for outgoing
calls. Instead, it auto-answers incoming calls and streams audio RTP
packets to the caller.
Default setting: no
SAS Enable
Cisco ATA 191 and ATA 192 Analog Telephone Adapter Administration Guide for Multiplatform Firmware
72
Voice Settings Configuration
Line 1 and Line 2 Settings (PHONE 1 and PHONE 2)

Table of Contents

Other manuals for Cisco ATA 192

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ATA 192 and is the answer not in the manual?

Cisco ATA 192 Specifications

General IconGeneral
Ports2 FXS ports
Network Interface10/100 Ethernet
Voice ProtocolSIP
Audio CodecsG.711, G.726, G.729
Operating Temperature0 to 40°C (32 to 104°F)
Storage Temperature-20 to 60°C (-4 to 140°F)
Humidity10 to 90% non-condensing
ComplianceFCC, CE, UL